Search results

  1. L

    GVA actuator issue

    Aside from the wire issue, there was a motor issue. I have received the new one and installed it. I am unfamiliar with adjusting the cams. Right now using the toggle switch it turns 90 degrees left and right of center. I need it to stop in the center and also turn the 90 degrees to the right...
  2. L

    GVA actuator issue

    I cut the wire further down, re connected all the wires and still only working in 1 direction. I guess I will see if I can get a new one under warranty as it’s only 6 months old.
  3. L

    GVA actuator issue

    I noticed that my wire from my valve to my automation panel got cut somehow. I respliced the wires and I used the toggle switch to test it. The valve only works in one direction now. It’s only 6 months old. Any ideas?
  4. L

    Pool cage issue

    Unfortunately I get a build up of pine needles but they are laying in top of the gutter guards and not in the gutter. I usually clean them off twice a year.
  5. L

    Pool cage issue

    It’s coming out along the edges where the support brackets are holding up the screen house.. water is getting in between the gutter and the screen house and dripping out.
  6. L

    Pool cage issue

    Where my pool cage attaches to my super gutter, I get a drip after it rains or even in the morning from dew or condensation. It is annoying. Someone suggested drilling weep holes to get the water out quicker. Anyone had experience with this?
  7. IMG_0285.jpeg

    IMG_0285.jpeg

  8. L

    Circuit name labels

    Anyone have any extra circuit name labels for the Easy Touch wired indoor remote PL4/PLS4 device that they might want to sell for less? I just need 2 labels for the air blower and the light. The one for the spa comes standard and the last button is AUX
  9. L

    Easy touch syncing issue

    Well I turned off everything at the panel. Reinstalled the unit and it started up. My question now is the backlight is always on. Is that the norm now? It is a pl4/psl4 easy touch wired.
  10. L

    Easy touch syncing issue

    I repoaced an easy touch indoor unit that was used that was given to me. First it said mismatched unit Load from outdoor panel. A few minutes later it came on and it says sync. I checked the software. It says the outdoor is 2.1 and the indoor is 0.00. Also the backlight on the indoor unit is...
  11. L

    GVA-24 valve

    Yes that’s the manual and I have a copy of it that came with the valve. What I can’t figure out is howto stop the actuator in the middle at 90 degrees so it doesn’t turn anymore toward the spa return and the right side at the 180 degree mark to shut off the pool return.Everytime I think I have...
  12. L

    GVA-24 valve

    Yes and that’s what I can’t figure out. I guess I will have to try to play with each setting and try to figure it out.
  13. L

    GVA-24 valve

    the spa spillway is always on. The problem is isolating the spa when the heater is on. At present the actuator has to be run by the switch because the cams are in the wrong position, which is what I can’t figure out. This is on the return side. The suction side actuator is fine.
  14. L

    GVA-24 valve

    I put the new valve in and no matter what I try I can’t set the cams correctly. This is a TORK brand if it makes a difference. I want the valve to stop in the center to allow the water to go to my pool and spa. When my spa automation is turned on I need the valve to rotate 90 degrees and stop...
  15. L

    GVA-24 valve

    I put the new valve in today and it was definitely the problem. Now I have to adjust the cams. I need it to stop in the middle so the returns are both open. Then when I turn on the spa the actuator turns to the right and closes off the pool return. What do I need to do to set this up? I haven’t...
  16. L

    GVA-24 valve

    I just replaced another valve so I took out the limit switches from the one that worked and still no luck. It’s just totally dead. I am replacing it tomorrow when I get the new one in I ordered. Thanks
  17. L

    GVA-24 valve

    Thanks for all the help. The ac guy came today and put the thermistor in, he didn’t even shut the power off when he opened the high voltage cabinet. He checked to make sure the heat pump ran properly all for $95.00
  18. L

    GVA-24 valve

    FYI I disconnected the new valve and plugged it into the other slot it worked fine. I tried the problem valve in the opposite slot and nothing. So I guess it’s the valve?
  19. L

    GVA-24 valve

    I have someone coming at the end of the week. Putting the thermistor in the pipe looks pretty easy but getting to the wiring looks harder. I was going to splice the wire but didn’t know if that was ok?
  20. L

    GVA-24 valve

    Last week I had a problem with my valve on the intake side. It made noise and would get stuck. I replaced it and it is fine. At the same time I checked to make sure the return side valve turned and didn’t make any noise and it was fine. Today when I put the system into spa mode the new valve...
  21. L

    Easy Touch 4 indoor control panel

    Tom, do you still have the Easy Touch 4 wired indoor controller we discussed a few weeks ago? Is it software 2.100 ? I decided to bite the bullet and go for changing the indoor unit. If it works fine if not I am out some money. Let me know. I have all your info and I will get a check out to...
  22. L

    Thermistor replacement

    It doesn’t look bad to open the panel and replace the thermistor. However, where do I plug the thermistor in? It looks like it goes into the box behind the heat pump control panel. That looks more complicated to remove. Can I splice the wires instead ? Thanks
  23. L

    Thermistor replacement

    I have an ultra temp heat pump that says the actual water temp is the same as the set temp of 104 on the heat pump panel. I was under the impression that this panel was inactive because everything is connected to the Easy Touch automation. Pentair told me to try to replace the thermistor. I can...
  24. L

    GVA-24 keeps clicking as it moves

    I turned on my spa today for the first time in more than a year. When I shut off the spa the valve got stuck. I used the toggle switch to move the valve. As it moved it would click after each inch of movement. I tried it again and the same clicking. Does it need to be replaced or is there away...
  25. L

    Pool heat pump issue

    Easy touch 5k42 with an indoor wired easy touch 4 panel
  26. L

    Pool heat pump issue

    Pentair ultra temp. After I turned the breaker back on , it went through a check of the water temp then the unit came on. Then it went through a 5 minute startup delay. Then it shut off. The screen on the heater says the spa temp is set for 104 and the water temp is 104 so it isn’t running. I...
  27. L

    Pool heat pump issue

    I went to put my heater on for the spa for the first time in years. The red light says service. The screen says alarm status five alarms. I just shut the breaker off and will turn it on to see if it resets anything. The unit is 11 years old. Any thoughts?
  28. L

    Easy Touch 4 indoor control panel

    I don’t think I am understanding what I am supposed to do.
  29. L

    Easy Touch 4 indoor control panel

    I have an intelliflo pump, salt cell, heater, solar panels. Everything is working. Yes the unit functions intermittently.
  30. L

    Easy Touch 4 indoor control panel

    I have not figured it out yet. It works on and off. Last week I had pressed the light button and nothing happened. However during the night the light came on. Last night I had pressed the blower motor and sure enough the blower came on during the night. It makes me think it’s the indoor unit...