Recent content by jeanft

  1. J

    New board on Aquarite does not work with no light or display.

    Thank you so much for the helpful comments. Working fine, so far. Are the rectifiers getting too much heat from the chassis? Any way to isolate them? The bad rectifiers were KBPC5010.
  2. J

    New board on Aquarite does not work with no light or display.

    Thank you. Tested red/black. Zero V. Is that the correct rectifier? GBPC3504?
  3. rect.jpg

    rect.jpg

  4. J

    New board on Aquarite does not work with no light or display.

    The rectifiers were "upgraded" to better ones by B&L Enterprises a few months ago. I was told that thermistors go bad because of overheating from rectifiers. Would the fuse die with this cable issue even if the board is not turned on? OK. The rectifiers might be bad...
  5. board 2.jpg

    board 2.jpg

  6. J

    New board on Aquarite does not work with no light or display.

    Thank you for your help. I did not contact them. New box installed with breakers. Have 50A in main. The 20A fuse on the board dies immediately when the breaker is on, even if the Aquarite is turned off. I assume the transfo on the top left could be the issue. All wires are correct, the 240v...
  7. J

    New board on Aquarite does not work with no light or display.

    375$ , new box, replacing the 3 wire Romex with 4...
  8. J

    New board on Aquarite does not work with no light or display.

    I guess they give you a high price for the subpanel and tell you for $5800, they can change the main panel which is old and needs to be replaced" Live and learn.:) Same story with plumbers, mechanics and more...
  9. J

    New board on Aquarite does not work with no light or display.

    Great. It will be fixed Monday. I received a quote from a different company. Pretty crazy to me.
  10. invoice.jpg

    invoice.jpg

  11. J

    New board on Aquarite does not work with no light or display.

    Ordered the parts for the subpanel. Pump and timer work. The fuse dies right away on the new board. 240v coming out, converted to 24, removed the black and red wires, same with a new fuse. I guess it's a bad board.
  12. J

    New board on Aquarite does not work with no light or display.

    OK. It seems that it's the breaker in the main box tripping. It happened in the past. I did a reset yesterday and the pump worked fine. The subpanel never trips. I will call someone. Thanks.
  13. J

    New board on Aquarite does not work with no light or display.

    240V. I thought it was the missing link. No luck. Nothing on display/diodes. Then the pump stopped, timer off. Has to be issue with breaker at pool or inside on main I guess. . Does this look OK? Thank you.
  14. 20240826_153758.jpg