Recent content by hockeytommy84

  1. H

    Raypack heater advice please.

    Just picked up a used Raypack 266k btu digital. For a decent price. Or so I thought. I was reassured by the seller that there was nothing wrong with the unit. I did my best inspection and against my gut feeling bought it. I decided to flush the pipes with hose water and inspect the unit...
  2. 20200809_221331.jpg

    20200809_221331.jpg

  3. H

    Distance required between top of skimmer gasket and pool liner track?

    @jimmythegreek is there a reason for this standard. I'm trying to keep my skimmer as high as possible so my shallow end doesn't get too shallow. I'm a taller guy lol. Was hoping I could get away with two inches maybe 3.
  4. H

    1-1/2” PVC to 3/4” conduit | 320 color logic

    @ImLon2 how long was your stub out for the nicheless light?
  5. H

    Distance required between top of skimmer gasket and pool liner track?

    I am in the process of setting up my skimmer on my concrete block pool build. What's the minimum or suggested distance I leave between the two (top of skimmer plate and liner track) on a vinyl liner install? It's top mount track fyi.
  6. H

    1-1/2” PVC to 3/4” conduit | 320 color logic

    Hey @jimmythegreek At what point can you make this transition. I was planning on using the same style niche less lights and was wondering if it's okay to run the 1 1/2 pvc back to the pool shed. Then transition it to the grey 3/4 conduit up to a deck junction box. Or is this a concern?
  7. H

    Using nichless pool lights. Conduit size and expert advice needed.

    I haven't narrowed down the light I'm going to use just yet. But leaning towards nicheless lights. Is there a requirement for how far away the pool light junction box can be placed ? I'll have to call an electrician buddy to see what Canadian code requires. Thanks for the help this forum...
  8. H

    Using nichless pool lights. Conduit size and expert advice needed.

    Hey pool experts. I'm looking for advice on pre planning a conduit run for my pool lights. If I go the nicheless led route would it be wise to use the same 1 1/2 inch pvc for the entire run back to the pump house that I've used for my returns? Can it be a straight run or do I require a...
  9. H

    Different size intake and return lines.

    Hi guys and gals, Just finalizing some stuff for my pool plumbing. I am running 2 inch pipe for my intake. Main drain and Skimmer, but was wondering if I should use 1.5" for my 3 returns? Or should it all be 2"? These are all home runs...
  10. H

    Need advice on pool pipe.

    I'm in Canada. Trying to place an order with Canpipe tomorrow.
  11. H

    Need advice on pool pipe.

    Appreciate the advice I was able to find some charts on the actual wall thickness between the two. If anyone cares I can post the differences. I was only entertaining the idea due to covid-19. Hopefully my farmer friend can source me schd 40 pipe as everything non essential is on lockdown...
  12. H

    Need advice on pool pipe.

    160 psi is what this pipe is rated for. At 79 cents a ft it was pretty attractive. However if the pros say sch 40. Then this is the route I will take.
  13. H

    Need advice on pool pipe.

    . Thanks for the reply crusemm. I found the same forum link but was curious as to why its okay for irrigation where they are pumping higher psi. Buried in the ground. SDR is just an acronym "standard dimension ratio". meaning ratio of pipe diameter to wall thickness of the pipe. its the 26...
  14. H

    Need advice on pool pipe.

    I have a friend that is a farmer and has lots of 2" SDR-26 PVC available. They use it for irrigation and handles some pretty high psi. Is it too thin compared to the recommended SCH 40?