Recent content by DirtyPoolz

  1. DirtyPoolz

    Old Heat Pump - When to fix vs replace

    So I got a new fan motor from amazon for $50. Took a while for me to hookup. But it’s working again! Thanks for the advise! A1404, 1/4HP 825RPM Condenser Fan Motors A1404, 1/4HP 825RPM Condenser Fan Motors - - Amazon.com
  2. DirtyPoolz

    Name that booster pump sound

    Thanks Guys! The sound isnt terrible. It was silent before. I emailed about the warranty already. The internet is full of stories of Pentair only honoring a 60 day warranty for self installs.
  3. DirtyPoolz

    Name that booster pump sound

    Thanks for the reply. I was pretty sure it was the bearings. Do the bearings have to be replaced now? Will they do more damage to the pump? Or is it a matter of tolerance to the annoying sound? Any videos on the Boost Rite(LA-MS05 ) repair? Or any booster pump bearing replacement? Its a...
  4. DirtyPoolz

    Name that booster pump sound

    I replaced this booster last year. It is a Pentair LA-MS05. It was whisper quiet for almost a year. In the last day or so its started making an ugly sound. I noticed the the flex tube on the top had bubbled by the pump. The bubble in the flexible pvc was restricting water flow. I do not...
  5. DirtyPoolz

    Old Heat Pump - When to fix vs replace

    I will uninstall the capacitor when I get a chance and test it.
  6. DirtyPoolz

    Old Heat Pump - When to fix vs replace

    I put a new capacitor with the same rating as the old one. I can turn on the heater. I hear it start to hum. I can then use a stick and push the fan. The fan will stay running. swamp rat -there isn’t a ton left of the fan motor name plate. I was able to make out 1.6 amps as well this...
  7. DirtyPoolz

    Old Heat Pump - When to fix vs replace

    It was dark but I read the existing fan make and model. emerson K55hxkfw 9515 Volt 208/230 Rpm 825
  8. DirtyPoolz

    Old Heat Pump - When to fix vs replace

    I replaced the capacitor. That didn’t fix the issue. Fan still doesn’t start on its own. does that mean it needs a new fan motor? Anyone want to link one that would work for an old raypak rhp 115.
  9. DirtyPoolz

    Old Heat Pump - When to fix vs replace

    I was able to push start the fan yesterday. I think that confirms its the capacitor. Took me a while to figure out which one i need online. Wanted to have it on hand so I only have to take it apart once. Think I found the right one on Amazon for under $15 with free returns. Looks like its...
  10. DirtyPoolz

    Old Heat Pump - When to fix vs replace

    Hi - We have a RayPak RHP 115 from 2005. It was working at the beginning of the season. The fans are no longer turning on. My best guess is its the capacitor. I have not taking it out to test. I just noticed this weekend it wasnt turning on. How long should a heat pump last? 15 years...
  11. DirtyPoolz

    Help me slam my green pool

    Vitamin c seems to be the answer. Since it’s everywhere an acid treatment seems to be in my future. Can I wait til end of August? Or is this something I should take care of now?
  12. DirtyPoolz

    Help me slam my green pool

    I jumped in to get a closer look. He basically dug ruts in the pool. Underneath was white. I can replicate what he did with a screw driver. I cannot get a sample. I can scrap the plaster out. Maybe it’s a stain.
  13. DirtyPoolz

    Help me slam my green pool

    So I had someone from a local builder swing by to look at replacing the plaster, coping, deck and patio. He said the plaster is old and needs replacing, its milling in the deep end etc. He took his big pipe he was testing the coping with and scraped off the material I have been trying to kill...
  14. DirtyPoolz

    Help me slam my green pool

    I assume concrete showing means its time to re-plaster. When we had black algae last year it was only it a couple of spots. None of these spots shown had black algae or were this color. Maybe some more pictures will help... Shallow end to deep end.
  15. IMG_5326.jpg