Recent content by damb

  1. D

    how to replace Jandy pro LED nicheless

    When he said compatible with Jandy did he mean the would work with aqualink or that they would fit the fitting?
  2. D

    Iaqualink

    i just installed a iq900 that I bought on eBay for very cheap. From what I have researched it is the same as the newer iq20 except the iq20 has updated wifi software. This wasn’t an issue for me because I was going to hardwire it anyway. I have a PDA 7.0 system and like everybody else i’m pretty...
  3. D

    Jandy PDA not controlling Raypak heater

    Pool Clown you're awesome worked like a charm. It's amazing that you have to got though this to get it to communicate with Aqualink.
  4. D

    Jandy PDA not controlling Raypak heater

    yes it work manually.
  5. D

    Jandy PDA not controlling Raypak heater

    I did both temp up to full and put it into remote mode and yes there a temp sensor in the pipes.
  6. D

    Jandy PDA not controlling Raypak heater

    My new Pda system isn't controlling my new Raypak heater. It seam I have done everything correct. Connected the wires to the Jandy board in the correct spots and put the heater up to full but the pad doesn't control the heater. Do I need to use a relay for the heater?
  7. D

    Jandy PDA switch light colour and pum issue

    they are controller by Jandy PDA
  8. D

    Jandy PDA switch light colour and pum issue

    Just wondering if anybody else has this issue. When I change the colours on my Jandy nichless lights, my Pentair VS pump switches speed for a few minutes and then go back to normal.
  9. D

    Jandy purelink to Aqualink

    I have pda system but the purelink does't show up in the menu. Is there wires that should go from the salt gen. To the Aqualink board. I can't fine anytime in the manuals.
  10. D

    Spa plumbing air line

    I understand what you're saying, but the waterways jet bodies have 1.5" air lines and the Hartford loop is already buried in concrete so the only option is to up size at the loop to the pad. Do you think this will help?
  11. D

    Spa plumbing air line

    That's what the jets have. Should I up size at the Hartford loop?
  12. D

    Spa plumbing air line

    Thanks Yes Hartford loop, 2.5" supply lines down to 2" at jets and the air line is 1.5". The equipment is about 3'-4' away.
  13. D

    Spa plumbing air line

    I'm just about to finish up the plumbing for my spa and I would to see if anybody know if the air lines should be looped. I can't seam to get to a few area so I was just going to tee off another jet and cap the one end.
  14. D

    Wall panel tollarence

    I completed installing all my panels for my 12'x24' pool and I wondering what the tollarences for a steel wall pool. I'm less then 1/8" off level for all the panels Conner to Conner I'm off about 1/4" from square. Most of my panels are within 1/8" from plumb one is a little more maybe 3/16". I...
  15. D

    Cantilever pool step and coping.

    That's what I was thinking but just want to make sure. Is there always a little gap between the liner track(coping) step gasket? It seams not matter what way I were to do it there would be a small area where the liner is not the track or gasket, maybe 1/2" or so.