    Intermatic PF1102T timer/freeze guard on a Superflo VS pump?

    Jim - thanks very much for that info. I'm also in DFW and the freeze control was good in that it was brainless. However, during a real cold spell I've never not thought about the pump running, so I can do it on my own. OK, going to take the timer back for a refund.
  2. C

    Intermatic PF1102T timer/freeze guard on a Superflo VS pump?

    Thanks, I can find no information anywhere about whether the Intermatic timer overrides the pump or if it's even possible.
  3. C

    Intermatic PF1102T timer/freeze guard on a Superflo VS pump?

    Had a power outage a while back, when the power was restored hours later I turned on the pump and there was a loud pop sound then a quiet hum from the motor but nothing was pumping. The pump was almost 9 years old, I said - screw it, not gonna bother trying to troubleshoot and replaced it with a...
  4. C

    Glue for PVC pipe into CPVC Jandy valve?

    I've read people say to use the Oatey red can All Purpose Cement. On the Oatey site they say this: I don't care about the cure time and no hot water will go through the pipes. I know they're two different kinds of plastics but has anyone used this glue and then the joint leaked?
  5. C

    Replace old DE Filter Grids or buy new filter?

    Robert, I have that filter and considered ditching it because it's old and the grids needed to be replaced. But I don't need a new manifold and we had to replace the pump this year, so I figured we'll keep it for now. If you're faced with paying someone $500 to put that stuff in vs. a newer...
  6. C

    Will this grid assembly fit my old PacFab DE filter?

    Gotcha, InyoRob. Thanks very much for doing that.
  7. C

    Will this grid assembly fit my old PacFab DE filter?

    I've seen that other assembly and know it will work. But I might as well buy a completely new filter at that price, which I don't need to do. Where specifically does Pentair say the one I asked about will not fit? The reason I ask is because on the amazon Q&A of the assembly I linked to, there...
  8. C

    Will this grid assembly fit my old PacFab DE filter?

    Thanks for your help. Here's the side label with info. I also emailed Pentair but haven't heard from them.
  9. C

    Will this grid assembly fit my old PacFab DE filter?

    I've got an older PacFab NSS-48 DE filter, stainless steel outside. I need to replace the filter grids and the threaded rods that hold everything together are disintegrating from corrosion, I don't think the manifold is cracked anywhere but it's old and I saw this complete grid assembly on...
  10. C

    Best way to plumb new pump and diverter valve

    Do people ever connect Sch. 40 pipes to the pump?
  11. C

    Best way to plumb new pump and diverter valve

    Sorry, one more question. I've got a Pentair Superflo VS that came with two non-hi-temp unions. Would you use those or hi-temp? Or not even use one on the suction side? The installer of our pump years ago used schedule 80 directly into the pump, no union.
  12. C

    Best way to plumb new pump and diverter valve

    Need to replace my entire pump and one diverter valve. Two questions: 1.) Since I'm also replacing the pump I don't know if there was a better way to connect the plumbing to that valve - or just copy what was done here, which is what the installer did last time, except there are no unions. I...
  13. C

    Power went out during hard freeze - pump motor likely shot

    Skimmers had about 1/8" ice on top, stuffed a bunch of noodles in them. Thanks