Recent content by Bloooo

  1. B

    One out of two valves not powering on

    Hi, my system has two pentair intellivalves and one of them is not powered on at all. The working valve seems to be fully functional. I'd like to try and troubleshoot this myself. What step should I take next? I'm considering taking the panel off the control system and checking the valve...
  2. IMG_20210211_181246.jpg

    IMG_20210211_181246.jpg

  3. 00100lrPORTRAIT_00100_BURST20210211181202883_COVER.jpg

    00100lrPORTRAIT_00100_BURST20210211181202883_COVER.jpg

  4. B

    Spa stopped heating but spillover started

    Thanks for the tips about the heat pump. I think the pool cleaner turned off the heat pump. I just turned it back on and will wait a few hours to see if it's back up to normal. Before no lights were on, but I just hit the on button and now it's spinning up!
  5. IMG_20200531_212513.jpg

    IMG_20200531_212513.jpg

  6. B

    Spa stopped heating but spillover started

    Yes I've had some luck! Thank you for the tips. I opened the spa drain and set the actuator to auto. In spa mode, the spa spillover stopped (which I think is good) and the spa eventually heated to 95 degrees. The target is 102 and it seems like it's unable to hit that amount even after a day...
  7. IMG_20200529_161247.jpg

    IMG_20200529_161247.jpg

  8. IMG_20200529_161251.jpg

    IMG_20200529_161251.jpg

  9. IMG_20200529_161028.jpg

    IMG_20200529_161028.jpg

  10. IMG_20200529_161021.jpg

    IMG_20200529_161021.jpg

  11. B

    Spa stopped heating but spillover started

    It is a new pool that was set up correctly by the builder, however I think it was just recently that a pool cleaner came through and that's when the spa stopped heating. I haven't touched the actuator or anything on the pad. If it's not too much trouble I would really appreciate some help on...
  12. B

    Spa stopped heating but spillover started

    Here are the details! One of the valves appears to be in service mode and the attached tan filter basket thing on the leftmost pump has no water in it
  13. IMG_20200529_141044.jpg

    IMG_20200529_141044.jpg

  14. IMG_20200529_141034.jpg

    IMG_20200529_141034.jpg

  15. IMG_20200529_141026.jpg

    IMG_20200529_141026.jpg