Recent content by bazzacad

  1. B

    Help with SunTouch Controller & IntelliFlo VS pump

    I have an older SunTouch Controller. The back of the board says Rev. A & the firmware is 1.0. I just purchased a new IntelliFlo VS pump, however when the SunTouch turns on the pump it always seems to be at a high speed. Since the pump's display is disabled, I don't know what RMPs it's running...
  2. 2017-05-12 10-07-39 AM.jpg

    2017-05-12 10-07-39 AM.jpg

  3. 2017-05-12 10-11-35 AM.jpg

    2017-05-12 10-11-35 AM.jpg

  4. 2017-05-12 10-04-46 AM.jpg

    2017-05-12 10-04-46 AM.jpg

  5. B

    Pump losing prime\suction after a few hours of running

    Thanks for the reply. Yes, that's a PVC coupler. Shop Homewerks Worldwide 2-in Dia PVC Sch 40 Coupling at Lowes.com I was actually having this issue before the coupler was there. Previously, the horizontal pipe threaded right into the pump. So I figured the threads must be leaking. I cut the...
  6. B

    Pump losing prime\suction after a few hours of running

    OK, I've installed a new Pentair IntelliFlo VS pump & a new Pentair Quad DE filter along with new piping on the pad. The pump primes just fine in around 15-20 sec. and I can see water rushing in from the suction line. After it primes there's a small quarter sized bubble in the top of the lid...
  7. IMG_4101.jpg

    IMG_4101.jpg

  8. B

    Quad DE start up with low pressure

    Thanks for the reply's. Yes I understand the psi shouldn't be high. The side of the gauge said start at 20 & clean at 30, so I guess I expected it to be around 20 at start up. Hence my confusion. ;-)
  9. B

    Quad DE start up with low pressure

    Filter is up to 5-6 psi now after about an hour & a half of running.
  10. B

    Quad DE start up with low pressure

    Pentair IntelliFlo VS, currently running at 1500rpms (also new)
  11. B

    Quad DE start up with low pressure

    I just installed a new Quad DE 60 filter (this is my first DE filter). I slowly added the 12 scopes of DE per the manual, but my presser gauge only went up to 2-3 psi. Does it take awhile for the DE to coat the cartridges? Or is mt gauge bad? Or did I not add enough DE? This is the scope I used...
  12. B

    Electrical question for my new pump & SWG

    Thx very much. I guess I skimmed over that page when I was reading through it as I didn't expect to put the IC40 on a separate relay.
  13. B

    Electrical question for my new pump & SWG

    I'm installing a new Pentair IntelliFlo variable speed pump (011018) with a new Pentair IntelliChlor IC40. I already have a Pentair SunTouch control system for automation I'm connecting to. The pump is connected to a dedicated circuit breaker on my electrical panel & has the low voltage...
  14. booster3.jpg

    booster3.jpg

  15. B

    New equipment pad layout for existing ppol