Recent content by barbourjay

  1. B

    Hayward Tristar900 motor blew during Helene

    Problem solved, to make sure the pump wasn't bad I turned on dip 1 and 2 and reconnect the display. Checked to makes sure it would run manually and it did. Switched the dips back to off and reconnect the omnilogic. Had to quick edit the new pump under the spa and pool in the omni with the new...
  2. IMG_0203.jpeg

    IMG_0203.jpeg

  3. IMG_0204.jpeg

    IMG_0204.jpeg

  4. IMG_0201.jpeg

    IMG_0201.jpeg

  5. IMG_0202.jpeg

    IMG_0202.jpeg

  6. B

    Hayward Tristar900 motor blew during Helene

    So I got the new pump plumbed and wired up like the old one and it's not working. Getting this error, "MSP_DEV_COMM_LOSS,Comm Loss Device:10011737e9 HUA:VSP" Going to attach pictures of the wiring. fist two pics are of the old pump and the next two are the wiring up of the new pump. tried to...
  7. B

    Hayward Tristar900 motor blew during Helene

    Pool builder didn't hand tighten any of the 3 unions on the pump and used channel locks to tighten them all down so after running to the store to get a strap wrench and get them all undone the old one is unplumbed and I've opened up the new pumps control panel and set all the dip switches to...
  8. B

    Hayward Tristar900 motor blew during Helene

    Thanks! I was told by someone at hayward that I have to edit it into each of my themes to get it up and working so fingers crossed it's as easy as setting it up for remote operation.
  9. B

    Hayward Tristar900 motor blew during Helene

    Like most areas on the coast we had some flooding and my pump won't work. Pump is as high up as it can be for now. Pool builder built up as much as they could but we are on the Anclote river so not much you can do when we have as much storm surge as we do. I had someone come out to give me a...