Recent content by airbur

  1. A

    Hayward Heater Clicking/Knocking

    FIXED. So my bad and apparently it was pressure out of the filter (need to install a gauge). I spent 30 minutes running water down it and churning the sand with my hand. It was a mess. After reassembly and fixing a very small leak in a pipe, the heater fired right up and has stayed on. I...
  2. A

    Hayward Heater Clicking/Knocking

    Wow....great info guys! Thanks. Yes, I can feel movement on the valve when it's making the noise that seems to coincide. Could that be caused by incorrect pressure? As in I need to adjust and check with Manometer? Or is it more I need to replace the entire valve. It's this one...
  3. A

    Hayward Heater Clicking/Knocking

    Anyone? Need to sort this out. I bought a Manometer so will check pressure tomorrow.
  4. A

    Hayward Heater Clicking/Knocking

    I’ve had a Hayward H150FD heater running a few seasons now. It’s been stored inside during the winter and installed 3 months each summer. Recently it’s started to show “Lo” which usually is an issue with the water pressure or pressure switch. I’ve gone through all the troubleshooting in the...
  5. A

    What is your heater/pump schedule?

    Anyone? I already use a solar cover...that's not really what I'm asking about.
  6. A

    What is your heater/pump schedule?

    Howdy. My setup is below in the signature. I'm wondering how to schedule the pump/heater running. The last few years I've used an auto timer that turns both on at 6AM and off around 5PM. The heater only runs as necessary to maintain temp. I know this isn't optimal as each night the pool...
  7. A

    New pump advice

    I started with a 12' Intex, then moved up to a 14'. I got sick of the Intex filters clogging and leaks everywhere so converted everything to in-ground hardware including the pump, sand filter, and heater. This is my 3rd year on this equipment and I upped the size again to 15'x48". It's...
  8. IMG_3256.jpg

    IMG_3256.jpg

  9. IMG_3257.jpg

    IMG_3257.jpg

  10. A

    In ground pool filter for AGP

    All my my AGP equipment is designed for IGPs...
  11. C50405E5-D409-4B09-8A05-8E5C8E6B4A5C.jpeg

    C50405E5-D409-4B09-8A05-8E5C8E6B4A5C.jpeg

  12. B20C7F08-DBB6-43A0-9FA6-D92FCAD189C2.jpeg

    B20C7F08-DBB6-43A0-9FA6-D92FCAD189C2.jpeg

  13. A

    One more pump won't prime thread....

    Problem solved! The 3 things I didn't think it would be....it was. I checked the pump drain plugs, cleaned and reseated them. Then I pulled the pressure gauge from the filter, cleaned and wrapped with new thread tape. System primed and is pumping! Thanks so much guys!
  14. A

    One more pump won't prime thread....

    Yep...it self primes and no issues last 2 years. Both intakes (skimmer and one on the other side) are clear and full of water. I checked the drain plugs for tightness but those are the only 2 seals I didn't pull. Will do that next. Thanks.
  15. A

    One more pump won't prime thread....

    The pump does need to pull it uphill 3' increase about 10' long...it's worked great for 2 years.