Search
Search titles only
By:
Search titles only
By:
Log in
Register
Search
Search titles only
By:
Search titles only
By:
Menu
Install the app
Install
Home
PoolMath
Pool School
Support TFP
Forums
New Content
Conversations
Unanswered threads
New media
Media
New media
TFP-TV
Search media
Members
Current visitors
Forum Rules
JavaScript is disabled. For a better experience, please enable JavaScript in your browser before proceeding.
You are using an out of date browser. It may not display this or other websites correctly.
You should upgrade or use an
alternative browser
.
Report
swamprat69
Well-known member
·
From
Las Vegas, NV
Messages
715
Media
12
Featured content
0
Reaction score
104
Points
0
Joined
Mar 30, 2019
Last seen
Today at 12:44 AM
Follow
Start conversation
Find
Find content
Find all content by swamprat69
Find all threads by swamprat69
Latest activity
Postings
Media
About
swamprat69
replied to the thread
Simplified (and cheaper) AC to Pool Heat Exchanger
.
You really need to know just what you are doing to attempt this. There is a reason for all of the parts and controls on the FPH system...
Mar 17, 2023
swamprat69
replied to the thread
Hayward vs Raypak/Rheem Natural Gas Pressure Requirements
.
As long as there is no significant pressure drop due to inadequate pipe sizing, either choice should be OK. I am running a 17 yr old...
Mar 11, 2023
swamprat69
replied to the thread
Hayward vs Raypak/Rheem Natural Gas Pressure Requirements
.
If there is a regulator installed by your gas meter then the nominal supply pressure would be 6" WC + or - 1"WC meaning the lowest...
Mar 10, 2023
swamprat69
replied to the thread
Hayward vs Raypak/Rheem Natural Gas Pressure Requirements
.
The 4" to 9.5" WC only applies to low pressure delivery sysytems where there is no service regulator installed. Is there a regulator...
Mar 10, 2023
swamprat69
reacted to
supersteel's post
in the thread
Hayward 2004 built H400IDL2 SF error code Battle
with
Like
.
Thanks Swamprat, used the hayward guide and replaced PCB. No codes anymore.
Mar 7, 2023
swamprat69
replied to the thread
Hayward 2004 built H400IDL2 SF error code Battle
.
You can use this thermister output table to get temperatures https://www.bapihvac.com/wp-content/uploads/2010/11/Thermistor_10K-2.pdf
Feb 25, 2023
swamprat69
replied to the thread
Hayward 2004 built H400IDL2 SF error code Battle
.
I have the same heater from about 2006. Haven't run into that code yet, but if sensor reads good (sensor has 2 thermisters that should...
Feb 25, 2023
swamprat69
replied to the thread
LRZ250EN NG not getting power to the gas valve and I replaced the ignition control with no luck. Any suggestions would be helpful.
.
I thought that you stated that the gas valve voltage climbed very briefly before going to 0 volts? If the fusible link is open, you may...
Feb 21, 2023
swamprat69
replied to the thread
LRZ250EN NG not getting power to the gas valve and I replaced the ignition control with no luck. Any suggestions would be helpful.
.
I would disconnect the 2 wires at the gas valve and measure the voltage at the wires with the valve disconnected to see if the voltage...
Feb 21, 2023
swamprat69
replied to the thread
LRZ250EN NG not getting power to the gas valve and I replaced the ignition control with no luck. Any suggestions would be helpful.
.
Can you confirm that the wiring/connection diagram is exactly as shown on the troubleshooting guide that you listed? I have to assume...
Feb 21, 2023
swamprat69
replied to the thread
Mastertemp 400 no ignition, low voltage to igniter
.
Took a look at the installation/users guide, this is the one that I got...
Feb 11, 2023
swamprat69
replied to the thread
Pool Heat Pump Leaking Freon
.
Has the heater been "recharged" multiple times? You need to realize that the electric motor that drives the compressor in the system is...
Feb 5, 2023
swamprat69
reacted to
1poolman1's post
in the thread
Raypak heater power switch
with
Like
.
Unless something changed (not likely), the switch swamprat69 referenced will work and cost about 75% less than one in a Raypak package...
Jan 24, 2023
swamprat69
replied to the thread
Raypak heater power switch
.
If you are talking about the On/Off rocker switch below the mode/temp adj/display, most are a press fit that snaps in when it is pushed...
Jan 22, 2023
swamprat69
replied to the thread
Jandy LXi Heater - No Blower
.
If you have 24V between gnd and 24VAC on the fenwal, your transformer and power feed are good. If you do not get 24V between gnd and W...
Jan 17, 2023