“Low” Calcium Okay with -0.18 CSI

Looking for feedback of anything looks troubling (especially low calcium).
I’ve attached my readings from Pool Math app. Gunite pool.
You need to get one of the two recommended test kits and post those results. Can’t really advise with what you have there.
 
  • Like
Reactions: .ben and PoolStored
You need to get one of the two recommended test kits and post those results. Can’t really advise with what you have there.
You need to get one of the two recommended test kits and post those results. Can’t really advise with what you have there.
I have a Taylor test kit. Very familiar with how to use it. Have used one for years. I recently bought a WaterGuru device and test weekly with Taylor and it’s close. Soooooooo, back to my original question.
 
I guess I didn’t word my question where it could be understood easily. I’m aware of the recommended levels which is why I’m asking the question in the first place. The CSI seems fine, but other levels are not in the recommended range.
 
They’re not.
Are they from the Guru? Can't get 6.7 FC on a Taylor kit, for example, would have to be in .2 or .5 increments. We'd like to see your results from your test kit.

I guess I didn’t word my question where it could be understood easily. I’m aware of the recommended levels which is why I’m asking the question in the first place. The CSI seems fine, but other levels are not in the recommended range.
You really want to use 250 CH as the floor for a plaster pool. Can you test your fill water for CH? You might be ok, if you have high CH fill. If not, adjust to 250.
We also recommend you round your CYA up to the next 10. Here's why...see #7:

Your FC is reasonable for your CYA of 60. Always follow this...Link-->FC/CYA Levels

Your TA is very high. If that number is from the Guru, I would encourage you to test again with your Taylor and report that. Would you also test your fill water for TA?
When the water warms up, your CSI will rise slightly. You may find that you need to lower your TA to keep CSI in check.

You didn't mention how you are chlorinating???
 
Are they from the Guru? Can't get 6.7 FC on a Taylor kit, for example, would have to be in .2 or .5 increments. We'd like to see your results from your test kit.


You really want to use 250 CH as the floor for a plaster pool. Can you test your fill water for CH? You might be ok, if you have high CH fill. If not, adjust to 250.
We also recommend you round your CYA up to the next 10. Here's why...see #7:

Your FC is reasonable for your CYA of 60. Always follow this...Link-->FC/CYA Levels

Your TA is very high. If that number is from the Guru, I would encourage you to test again with your Taylor and report that. Would you also test your fill water for TA?
When the water warms up, your CSI will rise slightly. You may find that you need to lower your TA to keep CSI in check.

You didn't mention how you are chlorinating???
Thanks, CH was one of my concerns. I have plenty of Calcium on hand to add, but hesitated when the CSI was in acceptable range.

Here are the Taylor results from tonight (yes, I use the WaterGuru automatic tester daily and weekly compare to Taylor):
FC: 6
CC: 0.5
pH: 7.6
TA: 220
CH: 300
CYA: 60
CSI: 0.24

For the time being, we're using liquid chlorine. The pool did not come with a SWG, but I had one in my last pool, and I MUCH prefer SWG, so I'm going to add one as soon as I can get a pool company out.

Thoughts?
 
That TA and CH make more sense.

Your Taylor test is the gold standard. Trust it. Fine to use Guru for monitoring, but use the Taylor for any adjustments. As you can see CH is higher, pH is higher, and TA is lower, Taylor v. Guru.

Test your fill water for TA and CH, and report those. My guess is your TA is high and CH is also.

Given the Taylor results, and new CSI, I would work your TA down.

Here is my link to the method...
 

Enjoying this content?

Support TFP with a donation.

Give Support
What Taylor test kit is that?
Add it to your signature.

As @PoolStored suggested, work the TA down. Will also be interesting to know your fill water ph, TA and CH.
When you add your SWG, you'll want to keep CSI slightly negative to minimize scaling in the SWG.
We recommend a CSI in the 0.00 to -0.30 (negative 0.30) range - especially with a SWG.
 
That TA and CH make more sense.

Your Taylor test is the gold standard. Trust it. Fine to use Guru for monitoring, but use the Taylor for any adjustments. As you can see CH is higher, pH is higher, and TA is lower, Taylor v. Guru.

Test your fill water for TA and CH, and report those. My guess is your TA is high and CH is also.

Given the Taylor results, and new CSI, I would work your TA down.

Here is my link to the method...
Thanks, I actually am familiar with the aeration strategy. We have a fountain and 2 bubblers, so I'm able to raise pH fairly quickly. So you don't seen any concerns on the CH front?