The control panel on my Pentair Mastertemp400 heater has stopped getting power. I’ve read other post trying to fix this myself, but I’m at a point where I don’t know what to check next. Any guidance would be much appreciated.
My system is about 15 years old and it’s a Pentair Easytouch control panel connected to a Mastertemp400 heater. We use the heater several times a week and it has been working fine for the last couple of years. I know that I have to have the spa on for the heater to get power. When I press the ‘spa’ button I no longer see “HEATER” displayed on my easy touch control panel and no lights light up on the heaters control panel.
Here is what I’ve done so far:
I checked the voltages on the heater and I’m getting 220VAC input and 28VAC out of the transformer. I checked the plugs to the control board and the 4-pin connector at J7 has 28VAC and the 5-pin connector at J1 has 0VAC (brd_vac.jpg attached). At this point I thought the control board was bad so I replaced it. The issue remained. Still no power. Next, I checked the wire between the easytouch control panel (J19) and the heaters firemans switch. I used a multimeter with audible continuity and verified that each screw post on J19 had continuity to the firemans switch post and they were not shorted together (fsw.jpg attached). What do I check next? I’m out of ideas.
Thanks,
-Mike
My system is about 15 years old and it’s a Pentair Easytouch control panel connected to a Mastertemp400 heater. We use the heater several times a week and it has been working fine for the last couple of years. I know that I have to have the spa on for the heater to get power. When I press the ‘spa’ button I no longer see “HEATER” displayed on my easy touch control panel and no lights light up on the heaters control panel.
Here is what I’ve done so far:
I checked the voltages on the heater and I’m getting 220VAC input and 28VAC out of the transformer. I checked the plugs to the control board and the 4-pin connector at J7 has 28VAC and the 5-pin connector at J1 has 0VAC (brd_vac.jpg attached). At this point I thought the control board was bad so I replaced it. The issue remained. Still no power. Next, I checked the wire between the easytouch control panel (J19) and the heaters firemans switch. I used a multimeter with audible continuity and verified that each screw post on J19 had continuity to the firemans switch post and they were not shorted together (fsw.jpg attached). What do I check next? I’m out of ideas.
Thanks,
-Mike