Hi everyone.
I have an Intelliflo 2 VST pump with a Hayward C5030 filter.
My pool service just cleaned the filters
The pump is currently running at 1500 RPM. According to my inline gauge, the flow rate is 30 GPM. And my filter gauge is showing 6 PSI.
Is 6 PSI reasonable? Or does it indicate an issue somewhere? (water bypassing the filter?)
In case it’s relevant , I’ll add that if I bump up to 2000 RPM, I get 53 GPM and 9.8 PSI. And at 2500 RPM, I get 70 GPM and 14 PSI.
Thanks!