My relay #1 and #2 are not putting out any voltage when turned on. Am I doing something obviously wrong or is it just a bad board? I have uploaded a video of my multimeter readings.
Hi Jeff,
I can grab a pic shortly. I had disconnected the low voltage light transformer hot and neutral from relay 1 after I realized it wasn’t working just so I could test with my multimeter. Going into the system I have line 1 (hot) and line 2 (neutral) powering up the system just fine. All automation is working via rs845 correctly and the app shows the system online. It’s just simply when I turn on relay number 1 or relay number 2 none of the 4 (2 per relay) contacts are reading any power.
I do need to leave the neutral feeding the intelliconnect though correct?
This is all 110 so there is no risk. Only black is hot.One thought on the way you have this wired. Wire colors could mean anything, which is why they need to be checked and not assumed. So I can't tell exactly what is going on, but in your picture, the load you are switching has a black, red and green wire. Is this a 240V application? If so, you need to switch both hots with the relay, or someone could get zapped when working on this equipment thinking it is off.