New VS pump, came home to no return flow and a full water basket at low RPM, help?

summertimesadness

Gold Supporter
Aug 23, 2022
393
New Jersey
Pool Size
20000
Surface
Vinyl
Chlorine
Salt Water Generator
SWG Type
CircuPool RJ-60 Plus
I've run this pump on SLAM at 2400 RPM with no issues.

Yesterday I programmed it to run 22 hrs at 1300 rpm and 2 hrs at 3200 for cleaning.

Came home today to find nothing coming from the skimmer returns and the SWCG on no flow / low flow. I opened the pump basket and water came pouring out. The pump basket wasn't dirty enough to warrant any blockage. I re primed it and all the air cleared the lines.

Of note, there is a slight water leak from the pipe on top of the pump that goes into the filter. It's going to be fixed soon.

Would this leak however cause this problem? Obviously low RPMs is causing the lines to become air blocked. Thoughts?

Hayward super pump vs 700 for reference.
 
I've run this pump on SLAM at 2400 RPM with no issues.

Yesterday I programmed it to run 22 hrs at 1300 rpm and 2 hrs at 3200 for cleaning.

Came home today to find nothing coming from the skimmer returns and the SWCG on no flow / low flow. I opened the pump basket and water came pouring out. The pump basket wasn't dirty enough to warrant any blockage. I re primed it and all the air cleared the lines.

Of note, there is a slight water leak from the pipe on top of the pump that goes into the filter. It's going to be fixed soon.

Would this leak however cause this problem? Obviously low RPMs is causing the lines to become air blocked. Thoughts?

Hayward super pump vs 700 for reference.
Low rpms dont cause an air blockage but low rpm might not be enough to close the flow switch in the SWG. Ideally you run 100-200 RPM above whatever rpm is needed to close the flow switch. Get the leak fixed and then check it.
 
Low rpms dont cause an air blockage but low rpm might not be enough to close the flow switch in the SWG. Ideally you run 100-200 RPM above whatever rpm is needed to close the flow switch. Get the leak fixed and then check it.

Correct on the SWCG. Its why I played with it and it runs fine at 1300 / 1400.

Would the pipe on the pump leaking create air pockets into the system? Just odd no water was returning in the jets.
 
Correct on the SWCG. Its why I played with it and it runs fine at 1300 / 1400.

Would the pipe on the pump leaking create air pockets into the system? Just odd no water was returning in the jets.
Are you sure NO water is coming out of the jets? Its gotta be foing somewhere. Are the return valves open?
 
Are you sure NO water is coming out of the jets? Its gotta be foing somewhere. Are the return valves open?

Yesterday when I came home, I put my hand in front of the jet and no water was coming out.

I turned off pump, drained the basket to see if there was any obstruction and poured water back in to prime it. After it primed, it pushed the air through and everything was back to normal.

I upped the timer speeds to 1800 rpm. I'll see this evening if it did the same thing.
 
Yesterday when I came home, I put my hand in front of the jet and no water was coming out.

I turned off pump, drained the basket to see if there was any obstruction and poured water back in to prime it. After it primed, it pushed the air through and everything was back to normal.

I upped the timer speeds to 1800 rpm. I'll see this evening if it did the same thing.
Check your skimmer weir doors to make sure they a arent stuck closed. Mine did that once and it caused air go get sucked in over time and then very little was being pumped through.
 
Check your skimmer weir doors to make sure they a arent stuck closed. Mine did that once and it caused air go get sucked in over time and then very little was being pumped through.

Possible, but I did look at them at first and it didn't appear stuck. I'll see this evening.

I think somehow air is getting into the system and it's creating a makeshift obstruction some how.

But it only happens on lower RPMs.
 
Your signature shows a 1 HP Pentair pump. Can you update that so we know what VS pump you are speaking of?
 

Enjoying this content?

Support TFP with a donation.

Give Support
With a heater and sand filter it is likely that low hp VS pump will not be able to be run at low rpm and move any water. I suspect the minimum will be 1800 rpm or even higher.

You would have been well served to get a full 3 hp VS pump.
 
With a heater and sand filter it is likely that low hp VS pump will not be able to be run at low rpm and move any water. I suspect the minimum will be 1800 rpm or even higher.

You would have been well served to get a full 3 hp VS pump.

I don't run the heater unless I'm home and I push it up to 2400 rpm.

After the heater is done, I turn it off and reduce the VS lower.

I didn't have the heater on at all yesterday.
 
Can you post a picture of your pad equipment?

Is the pump below water level?

Are there check valves in the plumbing? A broken check valve can have unpredictable behavior. Sometime open, sometimes closed.

When the pump first turns on via the timer, does it first go through a priming cycle (i.e. higher RPM for a few minutes)?

Air locks can only occur where the pump pressure is lower than the highest pipe.
 
Can you post a picture of your pad equipment?

Is the pump below water level?

Are there check valves in the plumbing? A broken check valve can have unpredictable behavior. Sometime open, sometimes closed.

When the pump first turns on via the timer, does it first go through a priming cycle (i.e. higher RPM for a few minutes)?

Air locks can only occur where the pump pressure is lower than the highest pipe.

1. Sure, ill do it tonight.
2. Nope
3. Not sure what to call it. Should be able to tell from the picture I posted.
4. It does, 5 minutes at 3400 RPM.
 
1. Sure, ill do it tonight.
2. Nope
3. Not sure what to call it. Should be able to tell from the picture I posted.
Did you post a picture somewhere that I missed?

4. It does, 5 minutes at 3400 RPM.
After priming and the pump steps down to the lower RPM, how long before the flow stops?