I'm trying to understand what caused this. The motor shaft on my Pentair Intelliflo VSF sheared off. Has anyone seen this before?


The details: VSF pump installed in 2019. Everything was fine one day, the next day the pump stopped moving water. Pump would start normally, but after a few seconds would throw an alarm due to lack of water flow. Opened the pump to find the motor shaft had sheared off flush with the mechanical seal at the motor. The now-detached portion of the shaft remains firmly attached to the impeller and appears to have a slight bevel at the failure point.
The motor turns freely and did not make any unusual sounds while running. We never had major leaks, but based on the condition of the motor housing we apparently had some. The impeller was clean so there should not have been excessive drag. Could the seal have caused this?
If anyone has any thoughts, ideas conjecture, I would love to hear it.
Thanks-


The details: VSF pump installed in 2019. Everything was fine one day, the next day the pump stopped moving water. Pump would start normally, but after a few seconds would throw an alarm due to lack of water flow. Opened the pump to find the motor shaft had sheared off flush with the mechanical seal at the motor. The now-detached portion of the shaft remains firmly attached to the impeller and appears to have a slight bevel at the failure point.
The motor turns freely and did not make any unusual sounds while running. We never had major leaks, but based on the condition of the motor housing we apparently had some. The impeller was clean so there should not have been excessive drag. Could the seal have caused this?
If anyone has any thoughts, ideas conjecture, I would love to hear it.
Thanks-