IC40 Union Seam Leak

JJ_Tex

Gold Supporter
Bronze Supporter
TFP Guide
Jul 17, 2019
4,078
Prosper, TX (DFW)
Pool Size
13000
Surface
Plaster
Chlorine
Salt Water Generator
SWG Type
Pentair Intellichlor IC-40
My IC40 is leaking at one of the unions, right at the "seam" where the two plastic halves of the nut come together. It looks like it was manufactured that way. Water is bubbling up at the seam and dripping onto the equipment pad. I can pinch the 2 sides of the nut together and the leak completely stops.

Is there an easy way to fix this, ideally without cutting the PVC? Would some sort of plastic weld/superglue be enough to stop it from leaking?

IMG_8995.jpgIMG_8996.jpg
 
If you can push both halves of the nut together, it isn't a "seam" it's a "crack".
Hope JamesW's linked fix works.
 
  • Like
Reactions: JamesW
Another option would be Plast-aid. I used it to repair my cracked SWG. It bonds extremely well with PVC, and it's unbelievably strong. Waterproof Plastic Repair Kits Fixes cracked ABS PVC Acrylic Wood More

6oz_400x.jpg
 
Did it work?
It seems a tad bit smaller. Amazon delivered it after dark so I didn’t give it my best effort. Heading to the lake but I checked before we left and the cracked union is still just dripping a very minimal amount.

I’ll give it a better shot tomorrow in daylight.
 
  • Like
Reactions: Newdude and JamesW
Ok, so here is an update for anyone else in this situation.
The split union above is a good idea, except it has an extra lip that prevents it from going on the pipe. I tried grinding down the lip using my dremmel, but that did not work well and I threw in the towel and looked for a plan B. Pictures of the lip compared to the normal IC 40 union below, plus my poor attempt to grind it down with a dremmel:
1694380595988.png
1694380674966.png

So, for my plan B I found this video in which he slices the new union to allow it to go onto the old pipe, then is secured by a hose clamp. So far it is working great. If the clamp fails I will post back. Hope this helps anyone else with the same issue.


1694380823866.png
 
  • Like
Reactions: JamesW
Also if anyone is looking for a good business idea, I recommend a split union that actually fits the IC40. From my internet searching there were many people experiencing the same issue and not many had a good answer other than redo a good chunk of pipe at their equipment pad.
 
  • Like
Reactions: JamesW
If it fails you have plenty of room to add a coupler.

Screenshot_20230910_173545_Chrome.jpg


You can either add a coupler, a couple inches of pipe and the new 2 piece union or just cut the pipe to slide the threaded collar off/on and cut a gap in the original pipe as wide as the interior of the coupler.

Its best practice to replace it all, but the stationary piece thingie is all but bulletproof and can be reused.
 
  • Like
Reactions: JamesW