I am finally getting around to installing the actuator valve I bought a couple of months ago. It is a 180-degree model (CVA-24 Compool which I think is Pentair? Doesn’t really matter, I guess).
I want to “automate” my fountain so when we want it on, I can make that happen. Currently, I have the return flowing into a 2” tee fitting where one side (2”) goes to the return jets with a two-way valve and the other side (1 ½”) is towards the fountain with a ball valve. Ideally, I’d like to have the option to have an option to select either return, fountain, or both, but I can’t seem to find an actuator that provides 3 stop positions, and I’m not sure if I need one. (Picture attached if it helps.)
Currently, (sometimes) I leave the ball valve open along with the return jet valve and when I want the fountain, I simply turn the two-way valve for the returns off (or close it partially) which allows me to leave the pump at 1200RPM with great flow at the fountain. So, here are my options, I THINK.
Thoughts for the group?

I want to “automate” my fountain so when we want it on, I can make that happen. Currently, I have the return flowing into a 2” tee fitting where one side (2”) goes to the return jets with a two-way valve and the other side (1 ½”) is towards the fountain with a ball valve. Ideally, I’d like to have the option to have an option to select either return, fountain, or both, but I can’t seem to find an actuator that provides 3 stop positions, and I’m not sure if I need one. (Picture attached if it helps.)
Currently, (sometimes) I leave the ball valve open along with the return jet valve and when I want the fountain, I simply turn the two-way valve for the returns off (or close it partially) which allows me to leave the pump at 1200RPM with great flow at the fountain. So, here are my options, I THINK.
1) Leave the plumbing as is and install the actuator on the current two-way valve to the return jets leaving the ball valve open and simply closing the actuator relay when I want the fountain. The drawback I see here is that when my pump spins up for 75 minutes every morning to skim the top a little more than the 1200RPM the fountain will run too. This isn’t a problem other than it will cause additional aeration when I’m already fighting PH with the new plaster I get that will hopefully slow down overtime.
2) Replace the ball-valve on the fountain return with a two-way and place the actuator on it. If I am seeing this correctly, that will require me to increase the pump speed because with water still flowing to returns there wouldn’t be enough pressure.
3) Buy another actuator and have them both change when I want the fountain on enabling me to leave my pump at the same RPM. I am not sure this is achievable with my automation, and I also see issues if one of those actuators or actions fail while in the closed position with pressure buildup.
I’m not necessarily opposed to changing the RPMs if there is a better solution. Just looking to find all my options to make the best decision. I also don’t HAVE to skim every morning, but it seems to help keep the pool nice and pretty.Thoughts for the group?