Last year, in the middle of pool season, we a pump fail and need replacement and I had an Pentair Intelliflow VSF-XF 3 HP pump installed. When it was setup, the flowmeter after the pump on the return line to the pool was also replaced (2" pipe, 2" flow meter). From when the pump was installed, it pretty much always reads "pressure limit" if you set the pool to a little above its required flow rate of 100gpm and seems to just run at maximum speed, but when its there, the flowmeter on the pipe reads 140 gpm. I then just turned down the flow speed until I got the flowmeter in the PVC pipe down to 110 gpm where I wanted that, and I've had to basically set the VSF to run at 65gpm to get 110gpm out of it.... its very reliable at that, it speeds up as the filter gets dirtier and keeps the same flow rate, and drops the speed of the pump back down with clean filters...
its working fine, other then me having to set the VSF to 65 gpm, but I'm curious as to what is wrong and how to fix this issue? From the look of the water flow, it appears the Pentair flow meter is wrong, and the PVC one is correct (and verified by putting the old PVC flow meter back in, which gave identical readings to the new one)
its working fine, other then me having to set the VSF to 65 gpm, but I'm curious as to what is wrong and how to fix this issue? From the look of the water flow, it appears the Pentair flow meter is wrong, and the PVC one is correct (and verified by putting the old PVC flow meter back in, which gave identical readings to the new one)