moved from here.. Pentair 2 Speed Pump Won't Start on Low Speed (Only)
Hello,
Digging up the old thread…mine is acting the opposite, won’t start on full speed. It would hum for a few second then stop. Have to wait a few second before I can even turn it on again (only to get the hum again). I have to start on half speed then switch over to full. How do you remove the rear cover to get to the springs or to clean the contacts? I removed the 4 screws but it won’t budge. Do I have to do anything with the “shaft access “ bolt/cover? Mine looks a little different at the wire terminals and it’s a Whisperflo High Performance WFDS-6, 2 speed.
I assume the problem is the same as the op’s . The capacitor looks normal and there is continuty between the 2 terminals.
thx
Hello,
Digging up the old thread…mine is acting the opposite, won’t start on full speed. It would hum for a few second then stop. Have to wait a few second before I can even turn it on again (only to get the hum again). I have to start on half speed then switch over to full. How do you remove the rear cover to get to the springs or to clean the contacts? I removed the 4 screws but it won’t budge. Do I have to do anything with the “shaft access “ bolt/cover? Mine looks a little different at the wire terminals and it’s a Whisperflo High Performance WFDS-6, 2 speed.
I assume the problem is the same as the op’s . The capacitor looks normal and there is continuty between the 2 terminals.
thx