Return Air Bubbles ????

Riddler0520

Well-known member
Jul 26, 2020
246
Charlotte, NC
Pool Size
23000
Surface
Plaster
Chlorine
Salt Water Generator
SWG Type
Jandy Aquapure 1400
New pool ownership is so much fun - will be glad when I figure all of this out

next question is around the deep end return jet (closest to pad). I have air bubbles coming out - you can see it a lot more at night with the white light on vs what you see during daylight

anyways - I’ve checked the motor lid O ring for debris and wiped it clean. The motor basket doesn’t seem to have excessive air - a medium bubble at surface under the clear lid

pool service mgr came by today to look at something unrelated and I had him look. He stuck a screwdriver insider the return to see if there was a piece of pebble or something creating blockage and he said “you have a 90 degree fitting in there”, he wasn’t sure why I had a 90 degree fitting but he then said that turn of water near the orifice is enough to create air as it comes out - and the famous phrase “nothing to worry about”

I have not replicated his test to see if I could feel the 90 bend but does this sound normal - if there is a 90 degree fitting inside (absent of knowing why it’s there), do you folks agree that could be the cause for air bubbles ?

what else should I be asking/doing and checking ?
68815700-B49C-4025-9D01-EA9F69823F67.jpeg
 
You have a SWCG. They create hydrogen gas that exits into the pool. Turn off the SWCG, wait a few minutes, and see if the bubbles stop.
 
Thread Status