New member
I know this is well late, but mine just failed and this fixed mine too. My system is about 10 years old. Thanks
Re: Aqua Logic Salt Too High - Cholrinator Off High Salt/Amp
PROBLEM RESOLVED!
The issue was caused by a broken/weak solder point on the K1 relay. I learned from some other discussion boards that this is common problem with the Aqua Logic/Hayward boards. The K1 relay did not need to be replaced. It only needed to be re-soldered. I will attempt to attach a picture. To check if this might be your problem, unscrew the mother board and turn it over, if there is black smoke/burn marks at the K1 relay solder point, this is likely your problem. It was an easy soldering job to heat up the soldering joint and add a little solder. Very simple and it saved me $600+ to replace the mother board.
I am shocked at how common this problem is but did not find any info on this board, so am passing it along. I also learned a couple other things from the other boards. 1st: high amps can "blow" the solder joint and that high amps are most often caused by salt levels being too high. For me, it was my practice to add salt directly to the skimmer boxes. This would certainly cause an extremely high salinity level as the salt was being dissolved and pulled through the system. In the future, I will turn off my turbocell before adding salt. 2nd: the motherboard has a 20 amp fuse on it. Unfortunately it seems the Amp limit on the relay is 20 amps too. It has been strongly recommended to replace the 20 amp fuse with a 15 Amp fuse to thus protect the relay and the K1 solder point. I intend to do this tomorrow.
I hope others find this info useful.
Depends on your board Rev, the pictures posted on pages 1, 4 & 5 of this thread might help.Can anyone send a much more detailed or at least enlarged picture of the where the K1 relay is located on the board.
Robert
Become a TFP SupporterOh, and my bride (of 48 years) says she has an idea what to do with the $600+ I just saved.