  1. G

    Pentair Intellitouch Board(s)

    Is there anyone that I could send my boards to for evaluation?
  2. L

    Pentair No Comm

    Having an issue with pentair system. Able to log in remotely and see things, unable to have an effect on the actual system. from the panel i'm able to change modes and have the valves turn, but no changes with the pumps. the pump settings in the panel appear to be correct when it comes to...
  3. L

    Pentair IC60 Salt Level not updating in the ScreenLogic app

    My IC60 is about 6 years old (I think) in a 20,000 gallon pool. (I know this is overkill for my pool size. But that is what they gave me!!) Im in New Jersey so it only runs 3-4 months a year. I have an Easy Touch system and the salt level in the Screen Logic app is not updating at all and is...
  4. T

    Pentair Mastertemp125 High Performance Heater Not Working

    Hello everyone, My name is Todd and I’m having an issue with my Pentair Mastertemp125 High Performance Pool heater not working. I have an above ground 21 foot round pool and I bought this heater in 04/2022 but it was backordered and I got it around the end of 08/2022 so it sat in my shed until...
  5. T

    Crack in conduit for spa side remote cable. How important to fix?

    Hi - My Pentair iS4 Spa Side Remote has gone bad and I need to replace it. How important is it that the conduit that houses the spa side remote cable be free from cracks? For context, the conduit that houses my spa side remote cable between the spa and the control system runs under a 10' wood...
  6. S

    Re-Pipe Recommendations? Help. Pictures!

    Here we go. Hello please help me, I am looking for any recommendations on my Re-pipe and filter upgrade. I've never done this but I'm really mechanically inclined, I work on all my own stuff, have lots of tools and eager to learn. Been doing hours of research. Background Info: Skip if you want...
  7. D

    New IC-20 reads "low salt" under about 80 degrees

    I recently installed an IC-20 (an adventure story all its own). It looked to be working fine, but then I saw that it was giving me a "low salt" reading one morning. I reset it a few times without success. Having read other posts on the matter, I thought maybe I have a bad flow switch, but the...
  8. O

    Relay Wiring question for IntelliConnect relays

    Hello, my original thread from the spring discussed some options for wiring my pump and SWG to a single relay so the SWG would only run while there is flow. Easy enough.... However, i've realized that i probably want to run on two schedules (the IntelliConnect only allows for a single schedule...
  9. Clayton Vandiver

    Pentair EasyTouch Low Voltage Relay breaker Issue!

    We have a Pentair EasyTouch 8 control system for our in-ground pool and exactly as another post back in 2016 had happen... this past weekend, following a fairly severe electrical storm, the Intellichlor salt generator was not working. When I investigated I found that the problem was that the low...
  10. M

    Which Pentair pump for this setup

    Hi all - What's the current-recommended Pentair pump for a spa. In the past I used Pentair IntelliFloXF Variable Speed Pump 3HP Max | Rotary Keypad Control | 022055 but now I see: This product is obsolete. The superceded product was not found. 1) What pump would you use for the spa 10x10...
  11. C

    Salt cell lights stay on when pump is off

    I have a Pentair Intellichlor IC40 attached to a Pentair Easy touch 8. When then pool pumps go off, or in service mode, the IC40's lights stay on. I recently bought the house with this pool, so I'm trying to tackle the learning curve.
  12. F

    Help with controlling old Pentair Intellibrite that turns itself off and on?

    I recently bought a house that came with a pool but no information about the equipment. It's all Pentair (EasyTouch control panel, cartridge filter, and pump), and there's a sticker on the panel that says the final inspection was done in October of 2013. The pool has a light that I believe is a...
  13. T

    Upgrading Waterfall - Add Pump?

    Hi - We finished our pool build last year, and have a new waterfall feature being added in the next 2 weeks to replace the one we threw together at the tail end of our build. Currently, we have a 2" line, tee'd off to (3) scuppers in slate stone. The IntelliFlo VSF is set to come on max RPM...
  14. gbhumphrey

    Hack a Pentair CCP320 into a CCP420

    My pool size is about 25,000 gals. I have a Pentair Filter housing CCP320. I USED to have a CCP420, but it cracked and the pool servicer replaced it with the 320. it seems my water was better wit the 420, so can I get a new lid that taller and the filter rack for 420 sized filters ? Would that...
  15. J

    Return jet not flowing, circulation seems poor but filter pressure reading normal?

    Hello- We had our pool opened on house we just purchased- it is a 16x32 in-ground pool with a Pentair CC200 filter and Hayward Superpump. Most of my experience has been with DE/Sand filters and Saltwater pools so thanks to this site for helping me learn some. We have one return jet that seems to...
  16. B

    Identifying 1970s Pentair Skimmer

    Is there any good way to identify an old skimmer? Is there any place that a serial/model # would have been molded into one of the parts? I need to replace a skimmer faceplate, gasket, and the entire set of faceplate screws and am having a hard time finding what I need. Thanks
  17. loki5

    Need help with Pentair / Screenlogic schedule **NEWB Alert

    Hi everyone, Need assistance in setting up a schedule for our "inground Cleaner" & "VSP Pool Pump". Question: If i setup pool pump to run 12 hours, say 8am to 8pm daily...and I have a schedule for CLEANER to run 1pm to 5pm daily, is this system smart enough to know when to run the Cleaner...
  18. J

    Pentair Superflo VST (VSP)

    So apparently the displayed speed on the pump we have (Pentair Superflow VST) is in RPMs how do I convert that to GPM so that I know how often my pool is being turned over? The pool company installed it and set up the VSP scheduled timing. I don't like to just trust others with my pool, I want...
  19. takeadive123

    (Solved) Pentair Screenlogic App no communicating with Raypak heater system to produce heat remotely

    My family just had our pool built last year and our pool installation contractor recommended/sold us the Pentair system. The system seemed great because our family rents out the home during the summer and with the Pentair Screenlogic app, we can control the heat for guests from outside the home...
  20. deilert

    Filter Keeps Clogging - Leprechaun bath

    My Pentair Quad DE 60 Pool Filter keeps clogging up. We've had to travel numerous times and always come back to a green pool. This spring has been bad. I've backwashed very frequently and pushed the Hayward Salt Water Generator (AquaRite 900) up to super chlorinate, but still ends up green...
  21. Fbskiracer

    Pentair Automation and SW Conversion

    I need convert to SW. I can't keep up with the pool and while I love my wife, the chemistry isn't her strong suit. I also need to replace our Dolphin M200 that came with the pool because its impeller/motor is not keeping it down. 20K gallon Vinyl. 4 lighted Pentair DeckJets, 2 Pentair...
  22. S

    IntelliConnect, IntelliPro, and iChlor installation

    Hi everybody, I just bought an IntelliConnect and wants to connect an IntelliPro and iChlor to it. Could somebody address me with some wiring diagrams on how to connect them. I've been looking at the manuals but I still have some doubts, specially with the iChlor. Any help will be appreciate...
  23. S

    VSP won’t pull water

    Hi all! I got a new Pentair VSP 2 years ago. Last year on startup it was fried and they replaced. Wouldn’t pull water. This year it’s running, but no water is pulling through. I’m afraid I will damage it leaving it running. I poured water in the basket, lid on tight. No plugs in skimmers...
  24. S

    Pentair Intellitouch Firmware Update

    Hello All, Long time lurker, infrequent poster here. I was poking around in my Pentair system and noted that we are running FW 1.170 where as the latest firmware is 1.190. I have already found and read through the thread telling me how to update the FW (including the programmers needed, the...
  25. H

    Pentair Hybrid Heat Pump/Gas Combo Heater App/Remote option?

    Hi all, we just installed a Pentair Ultratemp hybrid heat pump/gas combo heater for our existing inground pool. We have solar so we decided to do the hybrid unit to have the option to use gas or electric plus we live in SoCal so no worries with temps. The pool builder is giving me the option to...
  26. S

    Opinions on cartridge filters

    Hi there, I’m looking to replace my sand filter with a cartridge filter. I have a 4 year vinyl lined 26k gallon pool in upstate NY with a small amount of trees around at my neighbors property. The sand filter is fine I just want something that cleans a little better and less hassle of...
  27. P

    Intellivalve actuator not switching to Auto.

    Hi, My Pentair intellivalve actuator is not switching to Auto mode.i shows red light and and nothing happens when I press the mode button. This is causing water overflow from the pool and not heat up properly when spa is turned on. Have any of you faced this issue and is there anything I can do...
  28. P

    Intellicenter possible Glitch

    I have the i10PS IntelliCenter system. This issue is relate to the intellivalves. On my system there are 2 ports for Intake and return valves and 2 Aux ports labeled A and B. I was renaming Aux A and I called it Intake. The system defaulted that valve to the Intake and it removed the ability to...
  29. M

    Wiring and scheduling a VSF

    I am a first time pool owner and have a question about the wiring and programming of my Pentair VSF filter pump with an EasyTouch system. I think my pool builder made a mistake and wired my VSF filter to the load side. This meant the pump wasn't getting power unless the filter relay was...
  30. R

    Pool temp and chlorine generation

    My pentair salt generator is not producing chlorine even after cleaning. All lights are green. My pool supply guy says he has checked everything as far as chemicals go. He suggested that running the heat pump at high temperatures might be causing the issue. We like keeping the pool between 85...