Cell Usage
Pressing and holding the “More” button launches the System Status Mode. When the lights finish scrolling, the percent lights indicate hours of usage in 1,000s. For example, if the 40% light lights, that indicates 4,000 hours.
Flow Switch
The flow switch also contains a thermistor that senses water temperature. The water temperature is used for the salinity calculation. If the thermistor is failing the salinity will be incorrect.
Flow switch has 4 wires:
- Red/black - flow switch
- Green/whire - temperature sensor
With no temperature input, the cell defaults to a temperature of 77 Fahrenheit. The sensors are prone to failure. When the sensor fails and it's obvious to the software that the sensor has failed, it defaults to a standard temperature of 77 f.
High Salt
High salt error occurs around 4500ppm. The cell will continue generating chlorine with a high salt warning.
Low Temperature
The cell will stop generating chlorine when water temperate is below 60 degrees.
Displaying Cell Water Temperature
Version 3.1 on adds the ability to determine system temperature. Pressing the “More” button after the display shows 1,000s of hours of usage, will show temperature as follows:[1]
Lights | Temperature |
---|---|
No LEDs | Below 30F |
40% | 36 to 45F |
40% and 60% | 46 to 55F |
60% | 56 to 65F |
60% and 80% | 66 to 75F |
80% | 76 to 85F |
80 and 100% | 86 to 95F |
100% | 96 to 99F |
100% blinking | over 99F |
All LEDs blinking | Sensor bad |
Press and hold the More button until the lights scroll and note which % light lights up. Then, immediately press the More button again and see which % lights light up.
Cycle Time
The Intellichlor cycles the % generation in 5 minute intervals. If the % generation is set to 50% the cell will generate chlorine for 2.5 minutes and be idle for 2.5 minutes.