Difference between revisions of "AutoPilot SWG" - Further Reading

Line 11: Line 11:
  
 
The manifold also holds the [https://www.saltpoolguys.com/autopilot-pool-pilot-tri-sensor-assembly-apa0003/ Tri-Sensor] that detects water flow, temperature and salinity levels.
 
The manifold also holds the [https://www.saltpoolguys.com/autopilot-pool-pilot-tri-sensor-assembly-apa0003/ Tri-Sensor] that detects water flow, temperature and salinity levels.
 +
 +
[https://www.saltpoolguys.com/ SaltPoolGuys.com] is a good source for AutoPilot parts.
  
 
===Troubleshooting using Volts and Amps Guide===
 
===Troubleshooting using Volts and Amps Guide===
Line 19: Line 21:
  
 
Before you replace the Tri-Sensor due to incorrect salt readings try pulling the sensor connector and cleaning both unit side and sensor side of the connector with contact cleaner.<ref>https://www.troublefreepool.com/threads/autopilot-nano-tri-sensor.195713/post-1725528</ref>
 
Before you replace the Tri-Sensor due to incorrect salt readings try pulling the sensor connector and cleaning both unit side and sensor side of the connector with contact cleaner.<ref>https://www.troublefreepool.com/threads/autopilot-nano-tri-sensor.195713/post-1725528</ref>
 +
 +
===Adjusting Chlorine Output===
 +
 +
Chlorine output on the AutoPilot SWG is adjusted by changing the Power Level.
 +
 +
===Tri-Sensor Leaking===
 +
 +
The Tri-Sensor has an o-ring that can leak.  Pull out the Tri-Sensor and check the O-ring. Replace it if necessary and lubricate the o-ring with silicone lubricant.

Revision as of 22:48, 1 November 2019

Autopilot SWG

AutoPilot has various model Salt Water Chlorine Generators including:

  • Pool Pilot® Digital
  • Pool Pilot® Digital Nano,
  • Pool Pilot® Digital Nano+ Soft Touch
  • Pool Pilot® Nano
  • Pool Pilot® Soft Touch

The AutoPilot system uses a patented Bypass Manifold to limit flow through the cell to less then 20 GPM.

The manifold also holds the Tri-Sensor that detects water flow, temperature and salinity levels.

SaltPoolGuys.com is a good source for AutoPilot parts.

Troubleshooting using Volts and Amps Guide

AutoPilot has a troubleshooting guide on what the volts and amps mean in theior Volts and Amps Guide.

Incorrect Salt Readings

Before you replace the Tri-Sensor due to incorrect salt readings try pulling the sensor connector and cleaning both unit side and sensor side of the connector with contact cleaner.[1]

Adjusting Chlorine Output

Chlorine output on the AutoPilot SWG is adjusted by changing the Power Level.

Tri-Sensor Leaking

The Tri-Sensor has an o-ring that can leak. Pull out the Tri-Sensor and check the O-ring. Replace it if necessary and lubricate the o-ring with silicone lubricant.