  1. Pool Clown

    Stumped With This Easytouuch

    I know you dont have a spa, but does the ET? If the ET thinks (dip switches) you have a spa and it goes into freeze mode, it rotates the valves every so often (Pool/Spa) to circulate the spa plumbing and it locks out the pool cleaner. Or you dont have freeze enabled for the cleaner pump.
  2. Pool Clown

    Pentair Easy Touch help

    Glad to help. (y)
  3. Pool Clown

    Problem with Compool Cp3800

    I know this thread is a little old... Those units used to come from the factory with a "patch" cable (3 to 4 feet) attached inside the outdoor control box. If yours is still there you can remove your panel from inside the house, bring it to the outdoor controller and plug in your inside unit...
  4. Pool Clown

    Raypak - High 2 limit fault - checked unitherm governor, now what?

    Keep in mind that everything that the (pool) water hits is subject to the effects of your chemical dosing, good or bad. This is why some parts fail quickly and, coincidentally not covered under warranty.
  5. Pool Clown

    Hayward eCommand losing time?

    Sorry, i too am no help as i don't see many Hayward products.
  6. Pool Clown

    Mastertemp 400 Burner Problem

    Show a better pic of the igniters' grey area. May be able to tell if it has a crack.
  7. Pool Clown

    Jandy iAqualink can't control Jandy heater modes and temps (confused)

    If your automation is connected/configured properly (as designed), you shouldn't need to make any adjustments at the heater.
  8. Pool Clown

    Pentair EasyTouch help

    A NO COMM warrants an inspection of the transmitter and more importantly, the link between the transmitter and the E/T outdoor unit. The wire that is furnished with the transmitter is a solid core 2 pair. After time, or if the core was nicked while stripping for connection, it will be...
  9. Pool Clown

    Sta-Rite SR400NA won't keep temp

    Babysit the heater and see if it is cycling. It may not begin to cycle right away but rather once the water temp reaches a certain temp range. Make note of the temp at which it starts. if it starts at the mid to high 80's, then its probably the therm by-pass. Yes, I noted that you bought one...
  10. Pool Clown

    Hayward H400FDN - partially ignites

    So if you have the heater running without the cover and you replace the cover, the flame dies? Sounds like an oxygen deprovision issue. These heaters need to have the correct mixture of gas AND air, especially in the case of forced air appliances. They are alot more temperamental than...
  11. Pool Clown

    High limit problems

    Does it bang pop or groan just before it shuts down? Also, confirm that it is not plumbed backwards.
  12. Pool Clown

    MasterTemp 400 cuts out entirely

    You should check the temp sensor of the heater. You will know immediately if it has failed if the sensor is cracked. The Compool temp sensor and the heaters sensor are not one in the same. And they don't communicate with one another either. Set, or calibrate your automation temp with a known...
  13. Pool Clown

    Raypak heater faults and rusting out

    I would say stay with the brand you have, Raypak. If you decide to get a larger size (BTU) you will have to assess the gas line (size) to make sure it can handle the extra gas demand or volume requirement of the new heater.
  14. Pool Clown

    Raypak heater faults and rusting out

    A few things... Yes, those are the flame rails or burners. They have become disconnected from the jets and the heater should not run like that. Assuming that the heat exchanger is not leaking, the only moisture that you would get underneath the burners is condensate. Not only does the water...
  15. Pool Clown

    MasterTemp 400 cuts out entirely

    Yep, You want a TS5L sensor (linear), not the one that has all numbers as the part number (520272). Note: When putting the system into "Service" mode and hitting the heater button, you are turning the heater on with no automation thermostatic control, only the thermostat limit entered at the...
  16. Pool Clown

    Sta-Rite SR400NA won't keep temp

    Hold on guys, A flame sensing problem would only occur the first 3-10 seconds AFTER the heater fires, it would not keep the heater from initially firing. Pipe size? Maybe, but, i don't think it would allow the heater to fire for, say and hour, then decide the size was too small and not fire...
  17. Pool Clown

    Help with Start-up for Minimax PLus 400

    Sounds like the flame sensor is not proving. if you're comfortable with working on the heater, go ahead and clean the burner tubes/rails, and the gas orifices as well.
  18. Pool Clown

    Minimax 400 with PowerMax "Scortching"?

    Is your shed properly ventilated? Especially with a power vent, there needs to be plenty of air getting INTO the shed from the outside.
  19. Pool Clown

    MASTERTEMP 400 Combination Gas Control Valve Troubleshooting

    I suppose i should have mentioned that the manual i referenced is the Sta-Rite version of the same heater, the Mastertemp. Wiring, components, and schematic would be the same.
  20. Pool Clown

    MASTERTEMP 400 Combination Gas Control Valve Troubleshooting

    I would say board or Fenwal. Both high dollar components (of course). Both have a part in giving the valve voltage. The control board Tells the Fenwal to give voltage, and the Fenwal does the heavy lifting via a relay. You need to find out if the control board is brain dead, or if the Fenwal...
  21. Pool Clown

    Odd blower issue with Hayward H400FDN blower or???

    I was referring to the actual windings of the motor and not the wires that come from the motor. Are you saying that the motor shuts off altogether after the pre-purge?
  22. Pool Clown

    Odd blower issue with Hayward H400FDN blower or???

    I have had blower motors that are dying, still put out air, and run "beautifully". They just dont move enough air to either prove the air switch, or achieve the right air/ fuel mix to ignite the burner. See if you can see the windings of the blower motor through the motor vents. You are looking...
  23. Pool Clown

    Raypak Heater Repair or Replace

    First off, whomever you buy the headers from should ask you for the serial number so as to get the right part, if they dont, I would question that person, and maybe move on. The The flange is what you thread the plastic fitting into. Then the flange bolts to the header with the rubber gasket...
  24. Pool Clown

    Raypak Heater Repair or Replace

    With normal wear and tear, exposure, and maintenance, you can expect to see at least 10 years from a heater.
  25. Pool Clown

    Raypak heater always on?

    Probably not he board but the touch pad. Turn it off again, then unplug the ribbon cable from the side of the board and run it. If it stays off, probably a bad membrane (touch pad). A lot cheaper!
  26. Pool Clown

    Raypak Heater Repair or Replace

    Take the door off the heater and snap some pics of it to get an idea how its aging. And post the serial number, we can tell you how old the heater is.
  27. Pool Clown

    Pentair MiniMax 250 firebox material

    That's the stuff!
  28. Pool Clown

    Pentair MiniMax 250 firebox material

    No, it is not Asbestos. Here is a good explanation of what it is... Refractory
  29. Pool Clown

    Jandy LRZE check IGN control fault

    You can have a burner that "has been cleaned" but if the burner right next to the flame sensor didn't get cleaned thoroughly enough, you could have a lingering dirty/clogged burner problem that would explain the fault. With some heaters, the burner right below the sensor can be difficult to get...
  30. Pool Clown

    Jandy LXI - FAULT- CHECK IGN CONTROL - Appreciate help!

    Think about this... You have what looks like about 2 feet of 3/4" gas line from the heater to the shutoff valve. When you try to light the heater, the pilot valve opens and i.e. begins to purge out the air in that line through the pilot assembly. Did i mention that the orifice in the pilot...