Search results

  1. S

    IntelliChlor SCG circuit board JP2 and JP4

    So any of the JP2, JP3 or JP4 can be connected to the motherboard Comm port J4 or J5. OK thanks. I have two wires (a green and a yellow data cable) double connected on the same connector on the intellichlor connector. Should they be moved to one of the other comm ports on the intellichlor board?
  2. S

    IntelliChlor SCG circuit board JP2 and JP4

    Hello. What is supposed to be connected to JP2 and JP4 in an Intellicenter IntelliChlor SCG circuit board?
  3. S

    Suction side three way valve: 3 of 8 screws stripped (unable to tighted)

    I was able to repair it in so far as I can tighten (to then point where the magic lube is forced out), but not torque the screws. I used magic lube all around and then tested the spa. Once it goes from pool only to Spa only, still not getting basket full and flow seems to be inconsistent but...
  4. S

    Suction side three way valve: 3 of 8 screws stripped (unable to tighted)

    @ajw22 Fantastic! I'll give this a go! Thank you!!
  5. S

    Suction side three way valve: 3 of 8 screws stripped (unable to tighted)

    Pic of the suction side. The three red circles are the screws that I cannot tighten. The valve as pictured is in pool mode.
  6. 20230312_160054.jpg

    20230312_160054.jpg

  7. S

    Suction side three way valve: 3 of 8 screws stripped (unable to tighted)

    I have a suction side 3 way valve where I just replaced the the gaskets and valve door because I was having an air problem. When in pool mode I have no air in the pump view window. When I switch to spa mode I am not able to fill up the the filter and I loose suction, eventually causing the...
  8. S

    Inground spa jet fell out of socket - how do I put it back in?

    Hi @JamesW, thanks for this. Unfortunately I don't think this is the same as mine as mine does not have any threads to screw into the niche that it came out of :unsure: Could that part be stuck in the actual niche??
  9. S

    Inground spa jet fell out of socket - how do I put it back in?

    @RDspaguy incidentally what does "CPO" in your sig mean?
  10. S

    Inground spa jet fell out of socket - how do I put it back in?

    @RDspaguy Hello. Here is what it looks like...
  11. 20211010_214123.jpg

    20211010_214123.jpg

  12. 20211010_214130.jpg

    20211010_214130.jpg

  13. 20211010_214141.jpg

    20211010_214141.jpg

  14. S

    Inground spa jet fell out of socket - how do I put it back in?

    Hi all. The other day I was going outside to brush the pool and when I got to the spa one of the jet nozzles was laying in the bottom of the spa! See picture of nozzle. How do I put it back in? There does not seem to be any threads to screw it in, or any clips per se to clip it in there...
  15. 20211005_173606.jpg

    20211005_173606.jpg

  16. S

    Sta-rite Max-e-therm 200 natural gas heater, connected to Pentair Intellicenter, will not turn on using the Intellicenter

    PERFECT, that did it! So it was just the membrane pad that was bad. I REALLY thought that old control board was fried (given the look of the center chip lol). THANK YOU very much for your help, Poolbreh!
  17. S

    Sta-rite Max-e-therm 200 natural gas heater, connected to Pentair Intellicenter, will not turn on using the Intellicenter

    Ok, replaced membrane panel. Connected to Intellicenter, verified intellicenter relay closes when turning on spa heat. Heater powers on, then goes dark but I can manually turn on the heater by depressing wither the spa or pool button and it comes on and fires. Issue now is why will it not...
  18. S

    Sta-rite Max-e-therm 200 natural gas heater, connected to Pentair Intellicenter, will not turn on using the Intellicenter

    no response at all when depressing spa on the heater membrane panel (is it disabled when connected to intellicenter?). heater control board leds turn on (then go out) when selecting spa on Intellicenter but then nothing. I have not removed the intellicenter control wires and jumpered fireman...
  19. S

    Sta-rite Max-e-therm 200 natural gas heater, connected to Pentair Intellicenter, will not turn on using the Intellicenter

    Replaced the control board. When I tell intellicenter to turn on the heater, all led on the control board light up, for a few seconds, then go out and r14 appears in the display and then goes out. Then...nothing. Intellicenter thinks the heater is on (litttle heater icon is on) but no fire, no...
  20. S

    Sta-rite Max-e-therm 200 natural gas heater, connected to Pentair Intellicenter, will not turn on using the Intellicenter

    Went out and took some voltage readings...getting 120VAC in, getting the 24VDC turn on voltage from the controller. No led or anything. There was a wasp nest on the main chip on the control board and after I knocked the nest off, this is what the chip looks like (see attached). Looks...
  21. S

    Sta-rite Max-e-therm 200 natural gas heater, connected to Pentair Intellicenter, will not turn on using the Intellicenter

    Hi, thanks for the reply. I want to say YES to both (I know the temp in the intellicenter - 104 degrees) is set to greater than the spa water current temp) but can't say for sure about the buttons as I have no panel control being connected to the intellicenter (at least that has been my...
  22. S

    Sta-rite Max-e-therm 200 natural gas heater, connected to Pentair Intellicenter, will not turn on using the Intellicenter

    Hi all, I originally posted this in the Spas and Hot tubs forum, so posting here instead... So I have a Sta-rite Max-e-therm 200 natural gas heater, connected to Pentair Intellicenter, will not turn on using the Intellicenter. Not sure where to start with troubleshooting to see where the fault...
  23. S

    Sta-rite Max-e-therm 200 natural gas heater, connected to Pentair Intellicenter, will not turn on using the Intellicenter

    Hi all, So I have a Sta-rite Max-e-therm 200 natural gas heater, connected to Pentair Intellicenter, will not turn on using the Intellicenter. Not sure where to start with troubleshooting to see where the fault is. I have no display on the Sta-rite when I select "Spa (heater enabled)" on the...
  24. S

    Slow supply when changing from pool to spa mode

    @HermanTX Thanks sir, repaired/replaced the valve, restarted pump, verified pool supply was good then changed to spa, and when I did a "blob" of tangled sinewy "stuff" came out into the pump basket and I removed. Supply from Pool and Spa changeover now staying at same levels. Thanks!!
  25. S

    Slow supply when changing from pool to spa mode

    @HermanTX apologies, I may have misled with the verbiage. I did not reconfigure the system. I meant just changing the valves from pool mode to spa mode (from full open to pool for suction to full open to spa for suction, and from 75%spa/25% pool on supply side to full open to 100% spa supply)...
  26. S

    Slow supply when changing from pool to spa mode

    Some additional info: I noticed that in pool mode I am getting some air into the basket. Could a leak, possibly in the valve, be large enough to keep suction when in spa mode but then small enough that it is only letting a little air in when in pool mode?
  27. 20210121_203720.jpg

    20210121_203720.jpg

  28. 20210121_203653 (1).jpg

    20210121_203653 (1).jpg