Search results

  1. B

    Any luck replacing Hayward 250 H heater control board resistors?

    Re: Any luck replacing Hayward 250 H heater control board re The real problem seems to be humidity/water getting into the electronics. I was receiving CE errors after a rain but would clear up after the weather dried up. After a while the CE errors did not go away. I pulled both boards and...
  2. B

    CE error Hayward 250 H series pool heater, natural gas

    call them @ 908-355-7995 and explain to them you have the same problem as a number of other customers on the internet. Name the resistors etc. Be prepared to give them the name of your installer and they should send your installer a whole new set of boards. I paid a small fee to have the new...
  3. B

    CE error Hayward 250 H series pool heater, natural gas

    Has anyone learned why these boards blow out? Have a 3 year old 250h, had CE errors after rain storms but cleared after dry weather. However, now CE error will not reset. Any news? Update: I removed both boards and brought them in the house for a few days. Even though R15 and R45 have been over...