Search results

  1. S

    Safety cover during summer vacation: SWG adjustment ?

    Thank you for your reply. Just want to maintain FC during the trip, or minimally not drop below critical levels. Rather be on the safe side. Not looking to jump in on day 1 of the return, I can let extra FC burn off. I guess my question is, what is the impact of adding the safety cover and...
  2. S

    Safety cover during summer vacation: SWG adjustment ?

    Hello. We have decided to put our safety cover on during a 12 day vacation, its a high density mesh and darker in color (if that matters). Our water level is good, chemistry is good, CYA is 70, FC is ~6 when my SWG is around 40%. These numbers are without a solar cover during hot sunny summer...
  3. S

    Calimar 3HP VS Pump port size question

    I appreciate this. Online searches came up short. I did not show up on this list. Duke Energy was also listed for Ohio, but their website claims its discontinued. I will call my energy supplier as a last step.
  4. S

    Calimar 3HP VS Pump port size question

    Not sure if this is the best thread, but figured its worth sharing: Pool Supply Unlimited confirmed stock on the CMARVSP3.0 today, and via the chat they gave me a $25 coupon code "save25". So, I just pulled the trigger on this pump. Could not pass up <$500 before tax and shipping (which took...
  5. S

    Calimar 3HP VS Pump port size question

    Can I ask what you paid? I see this site has a lower price with the same quoted shipping. I wonder if Pool Supply Unlimited would price match.
  6. S

    Plumbing improvements during VSP upgrade - looking for advice

    Another question if you are able to help - when cementing the diverter valves in place, any concerns with PVC cement going into the valve area? Do people usually remove the guts of the valve during gluing? I highly doubt they did when plumbing my setup. Just wondered what was common practice...
  7. S

    Plumbing improvements during VSP upgrade - looking for advice

    Thank you for the replies and help. Also, I was editing my post while you were replying: Regarding that item, could it be a water bond instead of an anode? And if so, I assume I want to keep that in place?
  8. S

    Plumbing improvements during VSP upgrade - looking for advice

    Thanks so much for the input! You gave me confidence in my plan. I guess that is an anode and I never researched them until now. I read that it is traditionally placed between the filter and the heater, not sure how critical that is - mine is obviously before the filter. If I remove it, that...
  9. S

    Plumbing improvements during VSP upgrade - looking for advice

    I am looking to upgrade my 1hp single speed. I am thinking of jumping to the Calimar 3HP, which could be overkill but I have a lot of pipe length and elevation change so better be safe than sorry. Given the price, its a no-brainer. Yes, this pump might be Crud but I am ok taking the chance on...
  10. IMG_8045.jpg

    IMG_8045.jpg

  11. S

    Calimar 3HP VS Pump port size question

    I have been looking into this pump as well and found this thread. FWIW this was the response I received from Pool Supply Unlimited: "It is in transit and orders should be getting shipped out in the next 10days". I am on the fence about buying a cheap pump, but given how significant the...
  12. S

    Water level in FG pool + vacation question

    Just got back from my trip. Water is clear and the level was at the top of the skimmer from rain but not horribly high. I am pumping down to a reasonable level now and running my robot. Quick check shows chlorine is super high, 10 ppm. pH is high, but one drop of acid demand brings the...
  13. S

    Water level in FG pool + vacation question

    I don't have anyone, and I am the only one I know with a pool.... but I have a buddy who is smart enough I could trust him to stop over and take a quick peek. Things like cleaning the basket, checking the water level would be simple enough. chlorine just is what it is, nobody could help me...
  14. S

    Water level in FG pool + vacation question

    I have no overflow method, presumably it would rise above the FG tub and onto the edge of the concrete. Which seems bad. With crazy storms you could get inches of rain at a time, or without them, evaporate. For now I will just pump it down such that we could afford another crazy storm... but...
  15. S

    Water level in FG pool + vacation question

    I will start by saying I did some searches on vacation prep, I know its a well covered topic. We just got a lot of rain and the water level is just a couple of inches from the bottom of the 4" concrete decking around the pool. Over the skimmer. Highest its been. Typically I would pump this...
  16. S

    New pool house build & flooring selection: salt water compatibility

    This is a somewhat obscure question. We built a poolhouse on a concrete slab with a vapor barrier underneath. Ohio weather with temperature fluctuations, and its an unconditioned space. We are exploring a waterproof vinyl click-lock tile (the solid core with less expansion/contraction due to...
  17. S

    First spring. High water table. When to pump?

    Yes we have a 12" pipe out near the deep end, and yes finished off with a skimmer lid. The opening is barely large enough for a pump, but it fits. Since I have a high water table I always have spare sump pumps around. Before they poured the concrete I actually ran conduit and 1-1/2" PVC...
  18. S

    First spring. High water table. When to pump?

    Thanks for this. They backfilled with small gravel all around and "massaged" it in as they went. They backfilled at the same rate they were filling with water so the two levels went up together. I believe I have a main drain? There are two suction ports near the bottom of the sidewall in the...
  19. S

    First spring. High water table. When to pump?

    Appreciate your response. To be clear, I am not draining. I am basically asking under what circumstances do you need to pump around the pool. In other words, should I be concerned at all if my water table is 3' from the water level in the pool? 2', 1' ? At what point should people care...
  20. S

    First spring. High water table. When to pump?

    Hello all, this is my first spring as a pool owner. We have a high water table every spring, my two sumps in the basement run non stop for around 3 months, then they are dry the remainder of the year. We have 100% sandy soil conditions for what its worth. Right now the water table is about...
  21. S

    Struggle to lower pH after salt water conversion

    As an update, I left the cover off most of today. I tested pH just now and its 7.6 on the Taylor color scale. Not sure if it just took time for everything to kick in, or having the cover off for a period of time helped. All my levels are perfect now !!! I definitely learned a BUNCH with this...
  22. S

    Struggle to lower pH after salt water conversion

    Ok thanks. Yup, definitely don't have those. Only knobs I have turn the waterfall on/off and the neck water in the captains chair on/off. No knobs which control anything with the jets.
  23. S

    Struggle to lower pH after salt water conversion

    1) pretty sure I don't have air controls ? Its a Bullfrog spa. Had to google that. 2) honestly, and this is sad, I can't remember the last time I was in it. Now that cold weather is here, we intend to use it more... which motivated me to convert to SWG 3) no - I will google and begin to...
  24. S

    Struggle to lower pH after salt water conversion

    https://www.troublefreepool.com/calc.html Also used previous test results and recommendations from my local hot tub supplier / pool shop. They do testing and print out a report of what to add. Generally the TroubleFree Calc linked above seemed aligned with corrections I had made in the past...
  25. S

    Struggle to lower pH after salt water conversion

    Hopefully the attachments work. One picture I am holding up to the window / overcast sky so its backlit naturally (5785). One is with a white cabinet as the background (5786) Sky background for sure looks 8.0. Indoors I could argue its maybe closer to 7.8. Notably nothing like 7.6 IMO Up to...
  26. IMG-5786.jpg

    IMG-5786.jpg

  27. IMG-5785.jpg

    IMG-5785.jpg

  28. S

    Struggle to lower pH after salt water conversion

    Yes I will tomorrow, I assume I can attach on here.... I will attempt. FC is steady at 4.0 each day once I dialed in the generator.
  29. S

    Struggle to lower pH after salt water conversion

    thanks. as an update, my TA is now 50, but pH still looks 7.8-8.0 to me. "hot pink" is how I would describe the color via the Taylor kit. I will wait it out a bit and keep an eye on it. At this point I have put quite a bit of dry acid into the tub, and the TA has gone down for sure.
  30. S

    Struggle to lower pH after salt water conversion

    Again, I can't thank you enough for the insight. So, after adding 1.9oz (weight) of pH reducer yesterday, my TA is now 60, and pH is less pink... but certainly not orange like you start to see at 7.6. If I could guess I am around 7.8 or slightly lower. Given your last advice, I have a better...