Search results

  1. S

    My 2nd pool - What I don't like about it & the screw-up

    If mother nature and farmers being nice to my pool, this is the way it should be. All are underwater photos. Slime bag removed for cleaning. ============================ When villa was being built in 2017. August 2017 photo. See the amount of green towards the...
  2. DSCN4417.JPG

    DSCN4417.JPG

  3. DSCN4418.JPG

    DSCN4418.JPG

  4. DSCN4425.JPG

    DSCN4425.JPG

  5. DSCN4421.JPG

    DSCN4421.JPG

  6. DSCN4837.JPG

    DSCN4837.JPG

  7. DSCN4838.JPG

    DSCN4838.JPG

  8. DSCN4839.JPG

    DSCN4839.JPG

  9. DJI_0012.JPG

    DJI_0012.JPG

  10. DJI_0024.JPG

    DJI_0024.JPG

  11. S

    My 2nd pool - What I don't like about it & the screw-up

    NOW THE UNHAPPY PART 01. The screw up where I lost 1 drain. 02. Due to sudden change of plan for beer-shallow zone, now I do not have drain positioned strategically at 4 ends of pool. Scruppers at middle as planned but the re-location of 2 drains supposedly at the WAS beer zone, has made the...
  12. 1652885653200.png

    1652885653200.png

  13. a3.JPG

    a3.JPG

  14. DSCN5882.JPG

    DSCN5882.JPG

  15. DSCN5917.JPG

    DSCN5917.JPG

  16. DSCN5915.JPG

    DSCN5915.JPG

  17. DSCN3245.JPG

    DSCN3245.JPG

  18. DSCN1898.JPG

    DSCN1898.JPG

  19. DSCN1918.JPG

    DSCN1918.JPG

  20. S

    My 2nd pool - What I don't like about it & the screw-up

    STILL THE HAPPY PART The head is so low without sand filter and having big 2" manifold for a small 0.75HP pump with each water inlet/discharge to pool served by a dedicated pipe, I get pressure like a jacuzzi and that fits the shallow beer zone... :D Can't read any HEAD when filter element...
  21. DSCN4808.JPG

    DSCN4808.JPG

  22. Pump 1 - Complete Chart.JPG

    Pump 1 - Complete Chart.JPG

  23. Pump 2 - Complete Chart.JPG

    Pump 2 - Complete Chart.JPG

  24. S

    My 2nd pool - What I don't like about it & the screw-up

    This pool is only like 32,000 liters at best. 9.5m long x 3.7m wide x average depth at 90cm =31,635 liters. I never really bothered to measure though ...LOL. First, the HAPPY PART. 01. No sharing of pipes per pool inlet/discharge or suction. 1 pipe for 1 inlet/discharge or suction at the...
  25. DSCN0102.JPG

    DSCN0102.JPG

  26. DSCN0138.JPG

    DSCN0138.JPG

  27. DSCN4612.JPG

    DSCN4612.JPG

  28. DSCN4615.JPG

    DSCN4615.JPG

  29. a2.JPG

    a2.JPG

  30. S

    My 2nd pool - What I don't like about it & the screw-up

    Hi All, Been a long time since I last posted. I want to share my findings on my 2nd pool in Bali, where the plumbing + pumps + filter system I design/choosen. Size wise and shape I can't do anything about it. The availble space "X" size and condition "Y" is a given non-negotiable. Also due to...