Search results

  1. P

    Pump failure /freezing temps

    Perhaps you will know this answer... The drive on my machine is the SP3200DRZ2(B). It appears newer models of the tristar vs950 are equipped with the part you suggest. Do you happen to know if these are interchangeable? From what ive read, the newer models of the vs950 are mostly the same but...
  2. P

    Pump failure /freezing temps

    yikes, well at least ill have spare parts i guess
  3. P

    Pump failure /freezing temps

    Following up on the pump. Upon further review in daylight conditions, I have found the source of the burning smell. The gasket that seals the power board had a leak. A small amount of water made its way onto and rolled back on the underside of the board. I was able to clearly follow the water...
  4. P

    Pump failure /freezing temps

    Thank you for the quick response. I agree about the heater as well. I'll get to it in the morning.
  5. P

    Pump failure /freezing temps

    Pump wont run. It was running on freeze protect. Happened to head out to collect trash and realized the pump was not on. Breaker was tripped. Now it wont run at all. At first, i was getting a message pump not communicating with msp, i resolved that but the pump still will not run...I am in...
  6. P

    ColorLogic lights not working

    Thank you!
  7. P

    ColorLogic lights not working

    I have 4 of the 6 i installed here. LACUN11050 1u21076-109202 1u21088-110481 1u21076-109199 1u21088-110429
  8. P

    ColorLogic lights not working

    No. I installed everything myself from first scoop of dirt until now. I also received a replacement msp module last year as the one i had kept telling me it was registered to another user thus the automation was useless Overall, everything works excellent now. Pool is crystal clear and 75...
  9. P

    ColorLogic lights not working

    Moved from here. Im stumped. All firmware up to date. Lights are lacun10050 purchased last year, January 2021. Installed HVR1 to hayward transformer to lights. UCL mode works just fine. When i attempt omnidirect mode, the system asks me if the lights are flashing white. They are not. Ive tried...
  10. P

    OmniLogic MSP ID Changed?

    anything new? I have a ticket open with hayward with a msp id issue and it's been 2 weeks without a peep. Cant get through on phone lines...Hayward customer service taking a dump
  11. P

    Omnilogic MSP

    Nice find! i think you solved it!
  12. P

    Omnilogic MSP

    This is it. Nothing on the outside to hook into. I believe i have to tap into a j23 purple, but it's not clear how.
  13. 20210731_190659.jpg

    20210731_190659.jpg

  14. P

    Omnilogic MSP

    In this unit, the white and orange wires power the fan. I attempted this for a moment and the result was an operating compressor and an inoperative fan.
  15. P

    Omnilogic MSP

    it's the square heatpro... Omnilogic was ordered through poolwarehouse.com
  16. P

    Omnilogic MSP

    Hi folks I just installed my Omnilogic this week. Got everything automated except the heatpro heater (still no clue how it wants me to wire the J23) nor my Aquavac 6. The problem im really interested in is, why the Hayward app says "MSP ID Already Registered To Another User." I bought this...
  17. P

    Hayward Summit XL Heat Pump 140K to OmniLogic Question

    Im looking for more info on this as I am also struggling to figure this out (also setting up hayward 140k to omnilogic) I see two purple wires. Am i supposed to unplug the two purples and wire nut them together, then connect low voltage wire to the P and the S? Im doing a pool and spillover...
  18. P

    boulders during dig

    I looked and all i have are some pre patch pics and post vermiculite. What i ended up doing was using my own formula of 1b limestone, clay, and 4000 psi sacks of concrete mixed together with some water, and kept a very light mist on the sidewalls while applying. I really packed the stuff in...
  19. P

    Concrete Collar for Stone Coping on steel wall

    thank you this is a big help
  20. P

    What to do about spillover spa?

    Sure, it's 4 inch minimum concrete min 4000psi then add several inches of sand or limestone sand to level, level and ensure all weight is directed only on the slab, no weight on the upper lip. plumb and then backfill with sand or limestone sand, never use soil. Thats what i have.
  21. P

    What to do about spillover spa?

    The plan is for the spillover to be installed in this reverse radius. Here what we're seeing around the sight... both 2inch flex to and from the main pump, chose rigid 2 inch for the boost pump, and an electrical conduit line. The pool lighting conduit can be moved as necessary to accomodate...
  22. received_3916543385123691.jpeg

    received_3916543385123691.jpeg

  23. P

    What to do about spillover spa?

    Ok things are starting to move quickly and Im nearing the completion of my freeform diy pool build. One big problem is the spillover spa we purchased is still 3 months out from delivery. I havw the plumbing set up and lighting conduit run and ready, but otherwise a hole in the ground. Im trying...
  24. P

    Concrete Collar for Stone Coping on steel wall

    You mention a plasticizer...Is the purpose for that soley for strength? Getting close to this step. Bonding inspection next week. Also, given that we want max flexibility due to expansion and contraction, should the coping collar not be poured to go under the steel wall flange? I was planning...
  25. P

    Concrete Collar for Stone Coping on steel wall

    That's correct. Father in law is basically upset that i would challenge his plan for pouring the concrete. I believe he is well intentioned in only wanting to have the concrete truck coming one more time, but I planned for two more, possibly 3 more concrete days. My problem is he demands an...
  26. P

    Concrete Collar for Stone Coping on steel wall

    Hi Im looking for opinions on the collar pour. Father in Law claims he can pour both the collar and the sidewalk as one piece, and place the stones later. He says he is afraid to get concrete on the stones if they are placed first. I told him that sounds like a bad idea and risky if the forms...
  27. P

    steel wall skimmer gasket install

    yep. That looks similar to mine. There's no other way it could go. So much for the directions lol thank you!
  28. P

    steel wall skimmer gasket install

    I agree with you. However, the pool wall manufacturer's precut holes are way bigger than the gaskets provided by Hayward. That said, the skimmer throat fits nicely. It appears only way is one gasket on each side of liner.
  29. P

    steel wall skimmer gasket install

    Hi there I cant make sense of these instructions. Hayward 1084s with cork style gaskets, standard install. The directions show a gasket between the exterior wall and the skimmer, and other gasket between the inside of the liner and the faceplate, but both gaskets are sized for the faceplate...
  30. P

    boulders during dig

    That's a good idea, thank you... Havent gotten to dealing with patching the holes yet as im flying solo on this right now and turned my attention to leveling and plumbing the steel walls and running the main drains plumbing so i can get the collar poured..this sounds like a simple and quick...