Search results

  1. N

    Suction-side issue with spa draining to pool?

    True, the parts are more. But look at my plumbing there. If I replace the valve then I'm in for all-new plumbing from the spa, cleaner, and skimmer returns through to the pump, including a second diverter valve. I'd prefer to just buy a new valve and toss away the body.
  2. N

    Suction-side issue with spa draining to pool?

    Thanks, was thinking maybe similar. Is there an easy way to find the size/model of the diverter valve? I'd like to get the replacement parts before I open it, so that I don't have to do it twice.
  3. N

    Suction-side issue with spa draining to pool?

    Here are some pics. I included a pic of the skimmer basket to show this clue... with the spa filled and the pump turned off, the flow is all out of the skimmer and into the pool, strong enough to displace the basket. There is no flow into the pool on the return side as the spa drains out.
  4. IMG_2149 Large.jpeg

    IMG_2149 Large.jpeg

  5. IMG_2145 Large.jpeg

    IMG_2145 Large.jpeg

  6. IMG_2143 Large.jpeg

    IMG_2143 Large.jpeg

  7. N

    Suction-side issue with spa draining to pool?

    Came back home yesterday after a 5-day Thanksgiving trip to find my pool over-filled with water and my elevated spa completely empty. Everything was normal (of course) when I left on Monday. I read several threads about spas draining in this way, and they mostly describe a failing check valve...
  8. N

    Anyone upgrade the bulb in a Fiberstars fiberoptic light tower?

    Looks nice. Brighter than my 200W halogen ever was, though my system splits the light 6-ways.
  9. N

    Dolphin Active 30 only runs backward. Anybody experience this?

    Well, yes and no. The robot is working more-or-less as it should now. But I didn't do anything definitive to get it to work. I did use the coarse filters for several months, and with the robot working well enough, I put the fine filters back in to see if that would cause the problem to...
  10. N

    Pool Light Store LED lights: any experience?

    I want to replace my old Fiberstars fiberoptic system with LEDs. The Pool Store offers a house-brand system. It seems like a value when compared with an SR Smith PoolLux system. Has anyone tried it...
  11. N

    spa heat maxes out at pool setting or (95).

    Did you check the calibration of the thermocouple? I had a similar-sounding problem a while back. Spa would not heat up above 95 or so, but the water temperature was reading 104 on my controller. Basically, this water temp sensor was reading higher than the actual water temp and preventing...
  12. N

    Dolphin Active 30 only runs backward. Anybody experience this?

    Over the weekend I took the robot apart to see if I could find anything obvious. I removed the motor unit but could not open it. In doing so I found a small stick stuck underneath the metal plate on the motor's top cover. Plugged it in and ran it that way. It went through its cycle and...
  13. N

    Dolphin Active 30 only runs backward. Anybody experience this?

    Yes, it really didn't make much of a difference, unfortunately.
  14. N

    Dolphin Active 30 only runs backward. Anybody experience this?

    Hi Jim, Thanks, I'll check that review out. Hoping I don't have to drop a grand on a new robot at this juncture. It will not climb the wall backward, but they aren't supposed to. I can drive it manually forward and get it to climb, no problem. But put it in automatic cleaning cycle and it...
  15. N

    Dolphin Active 30 only runs backward. Anybody experience this?

    Hi all, I think my Active 30's behavior is somewhat akin to the below thread. The video by the OP looks just like mine. It starts up normally, but then will only move backward in increments of around a foot, then pauses for a moment. It repeats this cycle until it pushes itself against a...
  16. N

    Troubleshooting a Compool CP3000 - jet pump not getting power

    Woot! Bubbles! It finally worked. I guess the breaker was the culprit all along, though I think the pump needed to be rebuilt and likely was the root cause of the failure originally. Thanks very much for your help, @Ahultin ! And for anyone searching for pump rebuild info: The motor...
  17. IMG_7956 Large.jpeg

    IMG_7956 Large.jpeg

  18. N

    Troubleshooting a Compool CP3000 - jet pump not getting power

    In the above, I was measuring voltage across the switch when it was off. So on the right side one, with the blue wires, when the switch was off I measured 240V. On the lefthand switch, with the red wires, the voltage was 35V with the switch off. Very odd. But I think I did find the issue...
  19. N

    Troubleshooting a Compool CP3000 - jet pump not getting power

    They are both single-pole. The left one for example has 2 red wires and one green ground. Nothing on it's left side. I didn't get a chance to troubleshoot today. Will try tomorrow.
  20. N

    Troubleshooting a Compool CP3000 - jet pump not getting power

    I think 3, but it's hard to tell because the labels are cryptic. One says filter pump, and there are 2 that say booster pump. Today I disconnected the white wires at the Water Witch and capped them with wire nuts. So the Water Witch is out of the circuit now. no change to the voltages. Then...
  21. IMG_7947 Large.jpeg

    IMG_7947 Large.jpeg

  22. IMG_7949 Large.jpeg

    IMG_7949 Large.jpeg

  23. IMG_7948 Large.jpeg

    IMG_7948 Large.jpeg

  24. N

    Troubleshooting a Compool CP3000 - jet pump not getting power

    +1 to this and to checking the switch. Will do and report back. Though I believe that switch also controls the purple wires that lead into the block by the yellow ones... this is for the slide pump and it does have 240.
  25. N

    Troubleshooting a Compool CP3000 - jet pump not getting power

    Sorry, I buried the answer in the above post. The white ones seem to lead to the Water Witch. The red ones lead down a conduit to a toggle switch, and that switch kills the power to the pump. So I think the red ones ultimately lead to the breaker.
  26. N

    Troubleshooting a Compool CP3000 - jet pump not getting power

    Here are some more pics. One thing I discovered: the white wires leading into the black block measure 35V between them. They seem to lead out to the old Water Witch auto-fill controller which never worked. the red wires also attached at the same points lead down the right side conduit to two...
  27. IMG_7946 Large.jpeg

    IMG_7946 Large.jpeg

  28. IMG_7945 Large.jpeg

    IMG_7945 Large.jpeg