Search results

  1. E

    Pumps turns off after clean mode cycle

    Can confirm I think we found the issue. That One Touch cycle I had selected in the schedule ends with an “all off”, instead of reverting back to the baseline pump schedule. I set another schedule entry to kick the pump back on at 9A and that got it to turn back on after the all off command from...
  2. E

    Pumps turns off after clean mode cycle

    That’s an interesting idea, don’t change the clean mode and just restart the pump right after the clean mode ends to kick everything back on.
  3. E

    Pumps turns off after clean mode cycle

    Oh man, I hope we finally got this! Thank you for all this help walking through this. Will report back soon.
  4. A7F36C7B-4AD4-4651-97F8-6105B216B496.png

    A7F36C7B-4AD4-4651-97F8-6105B216B496.png

  5. 453C6437-19C5-4990-81CF-9A5202C9A59F.png

    453C6437-19C5-4990-81CF-9A5202C9A59F.png

  6. E

    Pumps turns off after clean mode cycle

    So after that last update, still a no go - pump cuts off after cleaning cycle. That Clean Cycle is a One Touch that came standard on my system.
  7. E

    Pumps turns off after clean mode cycle

    Here’s the schedule as of now with this latest feedback, plus the VSP screens.
  8. 86837EC1-A601-4A69-9E51-CBB8EEF525E6.png

    86837EC1-A601-4A69-9E51-CBB8EEF525E6.png

  9. 3C4F47E8-AD04-4765-8D3C-C72730B6B592.png

    3C4F47E8-AD04-4765-8D3C-C72730B6B592.png

  10. 30424741-6D14-4133-988C-5FF61677775A.png

    30424741-6D14-4133-988C-5FF61677775A.png

  11. E

    Pumps turns off after clean mode cycle

    No go - pump turned off after the clean mode after adjusting to this updated schedule.
  12. E

    Pumps turns off after clean mode cycle

    Awesome, I’ll give that a shot!
  13. 3E7AB51E-3F94-4BEB-9248-2F49E52585EE.png

    3E7AB51E-3F94-4BEB-9248-2F49E52585EE.png

  14. E

    Pumps turns off after clean mode cycle

    Has anybody had this issue before? My Jandy VS pump just cuts off when the “clean mode” cycle finishes on my system. The way I have the Jandy AquaLink schedules setup now is a 24-hour/day @ 1400rpm base schedule, and then a 7A to 8A clean mode cycle at 3,000rpm. I’ve troubleshot it to the point...
  15. E

    Pool Math Test Result Comments

    Ok, I figured it was! Thanks Maybe you’ll know this one - is there a way to enter adding water to the pool from say a hose? Something like if I was going to add Muriatic acid to the pool. I’ve got a timer on my pool fill hose, so I’ve kind of gotten a sense of how much water is added in...
  16. E

    Pool Math Test Result Comments

    Hey All! Is there any way to attach a comment to a test result that’ll show in the logs? I’ve been adding a note after until now, but just figured there may be an easier way? TIA
  17. E

    New Pool - Valve Settings

    This is fantastic - I’ll get my hands on an additional JVA and get this done! Thank you for the incredibly precise help.
  18. E

    New Pool - Valve Settings

    Just hopped into the web end of the system and here’s how the AUX are labeled thus far.
  19. 0684FB89-8B00-415E-AE42-7AF4CF7EB600.png

    0684FB89-8B00-415E-AE42-7AF4CF7EB600.png

  20. E

    New Pool - Valve Settings

    Ha! Definitely confirmed the fix followed the picture you guys sent over with the main drain and skimmer on the same actuator. I really appreciate all the help - it was invaluable on my end!
  21. E

    New Pool - Valve Settings

    @Ahultin hey guys! Heard back from the builder on this issue. He acknowledged the spa and main drain hookups are backwards, like we troubleshot so far in this thread. So after that change, and moving the actuators, should we be good? Are we able to have the separate pool mode/spa mode/spillover...
  22. E

    New Pool - Valve Settings

    Ran through confirming the spa jets versus the make up line. Here’s the first configuration, and the result (no jet output, water coming up from floor): Then I switched the valve over to what I have labeled as the jets, and here’s what we got: So I think we nailed down the return side...
  23. E1548582-7E13-47C5-8D60-AC1458B8D6DB.jpeg

    E1548582-7E13-47C5-8D60-AC1458B8D6DB.jpeg

  24. 88BEB594-93B0-4608-A028-8A0B289B7124.jpeg

    88BEB594-93B0-4608-A028-8A0B289B7124.jpeg

  25. 48D2AEC2-7B4E-4ED0-961E-5E6D458FE244.jpeg

    48D2AEC2-7B4E-4ED0-961E-5E6D458FE244.jpeg

  26. 2647E6B1-609E-4D31-AF63-DA879EA5C872.jpeg

    2647E6B1-609E-4D31-AF63-DA879EA5C872.jpeg

  27. E

    New Pool - Valve Settings

    Ok, and I see which valve you're pointing out in your photo with the notes on it - the first valve in order on the return side. I just responded above trying to nail down the drains, if that helps on that side of things.
  28. E

    New Pool - Valve Settings

    With it set this way, there’s the smallest amount of trickle over the spillover: With it set this way instead, the spillover is basically a waterfall within 20 seconds of changing from the prior valve setup above:
  29. 3031E5FC-D1A9-43DD-83D2-055BE3949DC4.jpeg

    3031E5FC-D1A9-43DD-83D2-055BE3949DC4.jpeg