    Hayward T-15 SWG / Omnilogic - Low current when K1 relay on, normal when K2 on

    Troubleshooting an issue with my SWG/Cell this year. System is now going on 6 years old. Noticed chlorine output was low and started digging. Taylor K1766 test kit salt reading is pretty close (2800) to the Omnilogic calc, so salt level is good. The average salt reading is out of whack due...
  4. T

    Hayward OmniLogic not registering water temperature

    Omnilogic will only display temperature if the flow sensor detects flow. So your issue may be with the flow sensor.
  5. T

    Hayward TriStar VS Pump won't turn on

    I looked in my pool log from last year and o had a similar issue (thought not an Omni Pl pump but mine is a vs). pump would not run, power was fine. Spun impeller with screwdriver, no issue not jammed. Pulled apart wiring cover didn’t see anything. Pulled Comms wiring off and repowered...
  6. T

    How do you delete a Site from Hayward Omnilogic Site List

    Interesting Richard, I just went through my portal and sure enough, could not find a way to delete a site or "Backyard". I suspect emailing Hayward is the only method at the moment since the MSP was registered already. Cheers Tim
  7. T

    Haywood heater clicking sound

    Likely the min. GPM flow switch inside the heater. Check your manual, it typically requires 40 GPM of flow. Normally on a Hayward there is an LED that will light up when there is not enough flow (interlock switches) and if that is in sync with that noise, you found it. Another test is to...
  8. T

    Hayward OmniHub sensors don't work

    I assume you have tested it but just wanted to make sure, OmniLogic won't display pool temp unless the flow switch has tripped (i.e. it detects the pump is operating). Very strange design.... so if your troubleshooting with the pool off, that might be it. Post your XML file and maybe we can...
  9. T

    Hayward OmniLogic R4.1.0 MSP Released - Remote Internet Update - No release notes at all

    Yes finally there though on the Canadian Website it still links to the old 4.0.0 firmware release notes, I had to change the URL to get the current: Release Notes for Firmware Revision R4.1.0 MSP/WDT/WLT/EPG June 15th, 2021 Features and Enhancements Omni now has the ability to configure...
  10. T

    Any news on iO line from Maytronics?

    Been watching for this one as well, now all the links are dead, videos are marked private. I suspect something happened....
  11. T

    Hayward OmniLogic R4.1.0 MSP Released - Remote Internet Update - No release notes at all

    Just got the notification today that a "New Update was available". Nothing mentioned on the Hayward site at all unfortunately. Performed the update, I went from R.4.0.1-b36874 on my MSP to R.4.1.0-b37122. No idea on what is changed as they did not include release notes anywhere that I can...
  12. T

    OmniLogic with Two Ecostar pumps

    Hayward VSP pumps have a built in HUA (Hayward Unique Address) so thankfully no dip switches etc to set. The Omnilogic should auto detect the HUA’s in config mode and let you select which HUA does what. You normally have to select the pump address box to get a full list of all the detected...
  13. T

    Filter top burst out of clamp

    That might be part of the issue... These are not meant to be adjusted with a wrench. I almost guarantee that the clamp has a very specific torque setting and therefore should be tightened with a torque wrench to the setting. You would have to check the manual.
  14. T

    Hayward Aqua Rite not recalibrating, Instant Salinity and Salt Level stuck at Zero

    Troubleshooting Guide: https://hayward-pool-assets.com/assets/documents/pools/pdf/troubleshooting-guides/aquarite-troubleshooting-guide.pdf?fromCDN=true
  15. T

    Clean canister of cartridge filters?

    Not sure on your particular model but with mine there is a drain plug at the bottom of the filter housing. I simply remove the drain plug and wash out the inside with a garden hose.
  16. T

    Hayward VSP Pump - No movement but powered up - removed comms wiring one and now fixed? Weird.

    Well I had a weird one this morning. omni logic showed that the pump wasn’t running late last night (no water flow) and same thing this morning. Checked the pipes, baskets and entire system everything clear, pump showed the proper RPM on the display (so the automation system was sending the...
  17. T

    Jandy Heater: High Flow Required?

    My Hayward requires over 40 GPM as I recall, if you have a FlowVis you can easily figure out what speed you need to achieve this. Otherwise just keep increasing the speed until the low flow light goes out and maybe add a few hundred rpm to be safe. For me that speed is considered Medium on my...
  18. T

    REPAIRED! - Hayward GLX-PCB-MAIN

    Interesting and great info. RTC chips don’t typically die so I’d be curious what in that design is causing those failures. Does that area of the board get excessively hot when it’s running or something?
  19. T

    I’m Mark Myers - trying to lower Phosphates

    I look at it this way, does Taylor include a method to test for Phosphates in their 2006 kit? If not, it’s not an issue...
  20. T

    Hayward automation stuff

    The sensors all connect to the left side of the main PCB. See image below. Three sensors are included with the Pro Logic. A water sensor and an air sensor must be installed at all times for proper operation. An additional supplied sensor can be used for either solar or dual equipment function...
  21. 2F4080FB-0896-416E-975C-36815FE09EC7.png

    2F4080FB-0896-416E-975C-36815FE09EC7.png

  22. T

    Hayward automation stuff

    I’ll check the manual one sec...
  23. T

    Should I convert to Mineral Pool system

    My neighbor converted theirs to Mineral (not sure which company, I’ll have to check) so I’ll see how they fair in a few years. They were told it was even less maintenance than salt... No chemicals to buy at all. hmmm fishy. I’m a huge salt fan especially here in Ontario, zero maintenance...
  24. T

    Flowvis has a digital model now!

    Turns out they have added a magnet to the moving plastic gauge inside and are likely using a Hall effect method to read the position of the gauge. So adding to an automation system maybe than we think. Once the retrofit model is out I may look at just getting the replacement valve insert and...
  25. T

    Flowvis has a digital model now!

    While I love my Flowvis FV-C flow meter, I've been dying for a method to see it remotely or to connect it to my Omnilogic system. Nothing drives me more nuts when I try to turn on the heater and the limit string has an error (usually just not enough flow due to skimmer needs a cleaning)...
  26. T

    Hayward automation stuff

    Did some more reading and it looks like replacing your GLX-PCB-MAIN for a GLX-PCB-PRO will convert your system from an aqua logic which is bloody ancient nowadays (early 2000’s) to a pro-logic system (manuals last updated in 2010). Aqualogic was made by Goldline and not Hayward. They were...
  27. T

    Hayward automation stuff

    All those parts are from the older Goldline/Prologic automation. they have since moved on to the Omnilogic line and really don’t seem to do much with the older stuff. If you were going to be upgrading any of those controllers make sure you compare prices to a replacement OmniLogic base system...
  28. T

    Hayward cartridge filter - why does it always leak?

    I’m going on a couple years with mine and no issues with leaks at all. However when I put mine back together I follow the torque specifications in the manual for the clamp. Maybe that makes the difference.
  29. T

    ColorLogic lights with Omni

    Dude this is awesome. Exactly what I was planning on doing. How hard was it to get the old lights out and replace them? I assumed you had to pull a pull string back through and replace the entire light and cable assembly by pulling the cable back using the pull string correct? I’ve been told...
  30. T

    Hayward ColorLogic Lights and OmniDirect Mode

    Watching this with interest as I am considering replacing my 2016 lights with the newer ones to get full control. However if Hayward botched it (again) I’ll hold off until they fix it.