  1. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    Thank you for your help. I am going to close this out. Jandy does not offer guidance on locating a repair center. The people that I have contacted from the Jandy site seem to want to measure voltages like I did to confirm the cell is bad. at $85 per hour then a cell is $600. I am sure it is...
  2. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    I'll try different people from the site then until I come up with someone who has service center capabilities. Thanks
  3. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    I did call Jandy and they will not test anything themselves. They gave me a phone number of a local technician. It was mentioned that the technician would measure the voltages and decide if the cell was bad. I mentioned that I had already done that and that the voltage was high. The cell...
  4. O

    Water softener- Salt free or Salt?

    It turns out that my house borders Riverside County and my city does not care if I use salt. As recycling water becomes more accepted and necessary they will turn up the heat on salt in the sewer systems universally. Until then it does not matter in most areas. People in California think the...
  5. O

    Water softener- Salt free or Salt?

    I am getting mixed information about the systems being legal in my area. I just became aware of this potential problem last night and will find out Monday morning. I am in Riverside County in the state of California. It might be that the problem is with commercial units at this time. I'll...
  6. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    Thanks. The outside post are in very good condition. I'll find a service center and have it checked out.
  7. O

    Water softener- Salt free or Salt?

    The Salt systems which remove the Calcium and Magnesium are not popular in my county any longer. Will a salt-free system reduce the hardness of my pool water if I swap some of the pool water out for salt free softened water? My understanding is this process only keeps the bad minerals materials...
  8. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    That is a very good idea. I may have a receipt problem since I purchased the house but I'll figure that out when I get to that point. I have attached a picture of the cell. I believe that the electrode has etched away on the right side probe. All indications are to replace the cell if the...
  9. Electrode.jpg

    Electrode.jpg

  10. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    That makes sense. I am in Palm Springs and the water is really bad. Very hard with a lot of Calcium. I'll look for a thread or start one regarding refilling the pool using soft water and my auto filler.
  11. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    The temp is correct and the Salinity are correct 3.1 and 83F. The SWG It did not like the boost and the service light came on again. code 120. I turned it off then on and it is running correctly. I'll run it a few days at the normal settings (40%) and see what happens. Over the weekend...
  12. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    You may have saved this SWG unit. The SWG has ran 15 minutes correctly with your changes. The cell shuts off and rests. I then up the percentage of time and the cell turns on. Turn the time down and it rests again without error. I am running it at boost right now for an hour. If it does not...
  13. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    Yes the adapter board is still installed. The program is on A. I could not find the firmware type without removing the PC Board. The software code that came up on the LED did not appear in any documents so I left it on A. I assumed that it only affected the salt water reading, I'll make those...
  14. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    The chord and salt sensor all appear to have been replaced with the new cell in late early 2019.
  15. box.jpg

    box.jpg

  16. Chord.jpg

    Chord.jpg

  17. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    Hi James, The model Number is a Aqua Pure 700. The label says both Aqua Pure 700 and Aqua pure 1400. A dot exists next to each model number. The dot is marked in alignment with the Aqua pure 700 label. This is a Aqua Pure 700. Is that the model number that you are asking about?
  18. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    Hello James, Sorry for the delay and thanks for the response. Here is a picture of the board. I have the system running and producing chlorine. It still stays in the reverse mode a long time and will generate the 120 or 121 low current error code. This will go away in a half-hour or after I...
  19. Board.jpg

    Board.jpg

  20. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    Thank you for this information. I'll post a Leslie pool supply report. I have fixed a few items . Getting ready to fix a few more. I'll start another thread
  21. O

    Older Jandy AquaPure 700 SWG cell ruined by exposure to high salt and chlorine?

    New pool owner through a house purchase 3 months ago. SWG unit worked well.The cell was new 6 months ago. Cell exposed to 4500 ppm salt and high chlorine. Pool guy is gone now after cell quit and chlorine was low. Drained the pool and salt is at 3200ppm now. Cleaned the cell with Muratic and...