    Pool lights.

    May work great for your pool. My pool was just too large.
  2. G

    Pool lights.

    Ordered them last year. Didn’t put out much light for my 30 foot pool. I had purchased something similar at our local pool store that was $30 for one. It was really good so I invested in 3 more. But they did not winter well. So I am looking for something else.
  3. G

    Pool lights.

    That’s why I don’t want to be the first ones to use them. Heheheh 😬
  4. G

    Pool lights.

    Has anyone ever used waterproof led rope lights. I was thinking of putting them just under eve of the pool rails. Any thoughts ???
  5. G

    Led strip lights

    Wondering if anyone has used waterproof led strip lights under the top rail of an above ground pool. If so how did they do and what kind did you use. I need my strand to be 100 feet long.
  6. G

    Weir door. Needed??

    Too dark I’ll post pic tomorrow
  7. G

    Weir door. Needed??

    Water level is not too low. If anything it may be too high
  8. G

    Weir door. Needed??

    It’s not stuck it’s like the pump pulls to hard and pulls it shut and therefore to qi not pull water just air.
  9. G

    Weir door. Needed??

    I have had a hard time getting my pump to hold a prime when starting up. I would prime and start them it would run and pull the door closed and pull air. After several days and doing everything I could imagine. I tried starting it again and holding the door down. And what do you know...
  10. G

    PVC step plans

    PVC planks
  11. G

    PVC step plans

    I have seen them built i was thinking filling the pipes with concrete to sink them and then using pad planks for treads. That should make them sturdy enough I think. dont you
  12. G

    PVC step plans

    Hello again. I am wanting to build a set of steps out of pvc pipe and boards to put in the pool. I have seen Photos of them. But not exactly for stairs or a pool. Has anyone ever built anything like this before.
  13. 21D3F16F-2EFF-4530-8019-664A0C7B68C9.png

    21D3F16F-2EFF-4530-8019-664A0C7B68C9.png

  14. G

    Gauge pressure too high

    With new gauge pressure is at 18. And zero when turned off.
  15. G

    Gauge pressure too high

    Problem finally solved. After several trips to the local pool store and all The help you all have been to me the problem is finally resolved. The problem was that there was air in the filter. After plugging all the skimmer and return and opening up the filter I filled it with water to the...
  16. G

    Gauge pressure too high

    Finally got the pump To hold pressure and it is working. But the pump basket is not full of water Is this a big problem.
  17. G

    Gauge pressure too high

    This system was all new last year and we didn’t get it up and running until the first of August. So it hasn’t been run but a few months total. That is why I can’t seem to figure out why it’s not all working fine.
  18. G

    Gauge pressure too high

    I have checked and double checked every connection. Been to the pool store multiple times today. Sho how to I fix the sand. Do I just need to replace all of it with. New ???
  19. G

    Gauge pressure too high

    The only other thing is. We removed part of the sand to move the filter and replaced it with the same sand. Can this be a problem. This is my last idea. !!!!! I am completely stumped. It will hold pressure when filter is closed.
  20. G

    Gauge pressure too high

    W water will not stay in the pump basket and it looses pressure at that point. Could it be the pump itself. ????
  21. G

    Gauge pressure too high

    After looking again. I have a seal. And I have lubed it. Did not work. Went to pool store. Talked with them. And replaced the hose from skimmer to pump. That did t work either. I am about at my wits end. Could it be the gauge again????
  22. G

    Gauge pressure too high

    Upon further inspection I find I have no o ring seal on the top of the pump basket cap.
  23. G

    Gauge pressure too high

    Upon further inspection I find I have no o ring seal on the top of the pump basket cap.
  24. G

    Gauge pressure too high

    Pump basket will fill with water easily. Just won’t stay once the pump is turned on
  25. G

    Gauge pressure too high

    We closed it last fall. Completely disconnected everything and stored it away. All water flows feeely. That’s why I don’t u see stand why pump basket won’t stay filled.
  26. G

    Gauge pressure too high

    Won’t won’t hold pressure to recirculate
  27. G

    Gauge pressure too high

    Have not treated the water yet this year. It look clear. With a dirt in the bottom of the pool. So no algee that I can tell.
  28. G

    Gauge pressure too high

    Not enough pressure to backwash
  29. G

    Gauge pressure too high

    Gauge came from Lowe’s. Pool store closed until tomorrow it will go up. When pump is full then when pump empties it goes back down.
  30. G

    Gauge pressure too high

    Here are a couple pictures. Hose comes from the skimmer to the front of the pump. Hose from top of pump to top of filter and from lower top of filter to return. No valves