Search results

  1. J

    raypak heater cfh, spk pilot lights, main burner doesn't

    fyi, I sent this email to raypak & they told me it was the board, too. Unit goes through CFH, then SPK. Pilot light successfully lights, however pilot light assembly continues to spark and main burner never lights. I have replaced the pilot light assembly, but that did not fix it. Trying...
  2. J

    raypak heater cfh, spk pilot lights, main burner doesn't

    no click, no gas smell. It was the board. I replaced it with this one http://discountpoolmart.com/product_inf ... cfd9c4c5ff and it works now. I hope this helps someone else & thanks for everyone's responses.
  3. J

    raypak heater cfh, spk pilot lights, main burner doesn't

    This is what I replaced: http://www.google.com/shopping/product/ ... CFEQ8wIwAQ
  4. J

    raypak heater cfh, spk pilot lights, main burner doesn't

    So, that's what my first thought was too & I thought I took care of that when I replaced the whole pilot light assembly. My understanding was that it was all part & parcel in there. Is that not true? It's an r206a.
  5. J

    raypak heater cfh, spk pilot lights, main burner doesn't

    Hey guys, Here's what I have: The unit does CFH. Then SPK. It lights the pilot but the pilot assembly continues to spark. The main burner never lights. I'm trying to follow the troubleshooting guide. It says at this point I should be getting 24v across the MV-MV/PV leads. I tested...