  1. H

    Jandy 1400 Aquapure

    Thanks for the help. I purchased a new sensor and the system appears to be working again. At least the temperature and salinity numbers make sense and the flow and cell on lights are on.
  2. H

    Jandy 1400 Aquapure

    I don't know if my sensor or my cell is bad. My troubleshooting points to the sensor being bad. Disconnecting the sensor connector from the front board and performing the three checks gives the correct readings. My "manual" says that the front board is OK, but the sensor is bad. Also, the...
  3. H

    Jandy Aquapure 1400

    Thanks Keven. I work out of town, so I just got back. I'll do the voltage check today. Thanks again.
  4. H

    Jandy Aquapure 1400

    I have a Jandy Aquapure 1400 that hasn't worked in over a year. Last summer I added chlorine manually because I didn't have time to troubleshoot it (I'm working away from home). The unit beeps about every two minutes and has a service light on. The error code is 170 which the manual says is a...
  5. H

    Wiring a Jandy Stealth SHPF

    thanks everyone, the pump is running like a champ...no smoke :party: Now I'm going to jump on the SWG thread and see why my Jandy Aquapure 1400 hasn't worked in a year. Thanks again for the help.
  6. H

    Wiring a Jandy Stealth SHPF

    OK, I'm convinced. The red wires go to L1 and L2. BTW, that's the way the motor label says to do it. The internal white wire on L2 had me concerned, but I'm over it. I can't explain my misgivings. I'll let you know how the smoke test goes tomorrow. Thanks again for your help.
  7. H

    Wiring a Jandy Stealth SHPF

    Sorry, I should have mentioned the ground. It's clear that the ground wire goes to the green screw. L2 already has an internal white wire plugged in there. That leaves L1, A and B terminals for my two red wires. I would think that one of them goes to L1, but I don't know where the other one...
  8. H

    Wiring a Jandy Stealth SHPF

    I have a Jandy Stealth SHPF 1.5HP pump wired internally for 220V. The terminal strip has three available connectors labeled "A", "L1", and "B" (a white wire is attached to "L2"). I have two red wires. Anyone know which of the three terminals they go to? Guess I should have looked more...