    Stenner pump injection port location and configuration

    Run it down and refill with fresh chlorine. Liquid chlorine looses strength over time and when warm so continually topping it off will cause you to always have weakened bleach. I buried my tank to keep it as cool as possible.
  2. J

    Installing Smaller Impeller In Pump

    Do you have info on the variable speed motor?
  3. J

    Installing Smaller Impeller In Pump

    Can I put a variable speed motor on this existing single speed pump?
  4. J

    Installing Smaller Impeller In Pump

    Just curious, how come the parts list shows the original SPX3210C impeller to be 1 HP when it’s a 1.5 HP pump?
  5. J

    Installing Smaller Impeller In Pump

    I already have a bad motor and the impeller needs to be pulled to replace the motor. Also, a Jandy valve would be quite noisy when it’s throttled down and I want to save energy.
  6. J

    Installing Smaller Impeller In Pump

    Thanks James. The motor shorted out and blew the breaker. I ohmed Out the motor and it has an open winding so the motor needs to be replaced. I figured while I was in there replacing the motor, I would put in a smaller impeller since the impeller has to be removed from the shaft while replacing...
  7. J

    Installing Smaller Impeller In Pump

    Hello all, I have a Hayward 1 1/2 HP water feature pump Model # SP3210X15 that moves too much water. It serves my rock water falls and 2 bubblers on the sun deck. The water flow is too much and too noisy. It’s hard to have a conversation when it’s running. Can I install a smaller impeller on...
  8. J

    Stenner pump injection port location and configuration

    I just drilled a hole (through a coupling for extra thickness), tapped the hole with a 1/4” NPT tap, and screwed the injection port directly in the hole. I electrically interlocked my Stenner pump with my main filter pump so the Stenner can’t run without my filter pump running. I also used an...
  9. 7C1BC685-52FC-4172-8143-1FE6D5E65943.jpeg

    7C1BC685-52FC-4172-8143-1FE6D5E65943.jpeg

  10. 1D724C3C-052E-4D57-9AE4-15F2F6B24E3D.jpeg

    1D724C3C-052E-4D57-9AE4-15F2F6B24E3D.jpeg

  11. J

    Stenner Pump Tubing

    Does anyone have an Amazon link to buy the black 1/4” tubing and fittings to use on Stenner pumps? I use Locke Well and Pumps for my Stenner parts but I just need tubing and fittings. I want it quickly and don’t want to pay shipping for such a small purchase.
  12. J

    Aquapod 2.0 Battery

    UPDATE: Been almost 2 years and the replacement battery is still working great!
  13. J

    Automatic Fill/Level Monitoring

    I want to clarify the sensor is wireless from the sensor through the hub to the relay controlling the sprinkler valve. There is a small wire coming out of the bottom of the sensor going into the pool. I mounted it on the backside of the pool in an inconspicuous place.
  14. J

    Automatic Fill/Level Monitoring

    Mine works fine. I cut the 3/4” PVC pipe after the manual fill valve/back flow preventer combo and installed the sprinkler control valve.
  15. J

    Automatic Fill/Level Monitoring

    I went with the Yolink and it works great. And it IS wireless. I used a standard sprinkler valve and wireless relay instead of the motorized valve.
  16. J

    Peristaltic pump for swimming pools

    My Hayward Pro Logic pool controller had a couple extra unused relays and I used one of those. It has to be interlocked with the main filter pump so it won’t run without the filter pump running.
  17. J

    Automatic Fill/Level Monitoring

    Thanks Billy. So your motorized valve controller is hardwired off of a power supply and not 4 AA batteries?
  18. J

    Automatic Fill/Level Monitoring

    Can you post a link? I’m having trouble finding it.
  19. J

    Automatic Fill/Level Monitoring

    Thanks for the info! I decided I’m going to go this route instead of the $675 LevelSmart with a small change. I want to use this relay with a sprinkler valve and transformer instead of the motorized valve you listed. https://shop.yosmart.com/products/yolink-relay Reason being I don’t want a...
  20. J

    Automatic Fill/Level Monitoring

    I almost pulled the trigger on the LevelSmart system but came across this thread and you definitely caught my attention. A couple questions. Does wave action in the pool cause intermittent opening and closing of the valve? If so, is there a way to program through the app to prevent this like...
  21. J

    Re-banding cartridge pool filters?

    I’ve thought about using HVAC Panduit straps used for connecting flex duct. (Looks like big wire ties about 2 1/2 ft. long) but haven’t tried it yet.
  22. J

    Adding Auto Fill To Existing Pool

    Good information! Thanks!
  23. J

    Adding Auto Fill To Existing Pool

    I’m looking for a practical way to add an auto fill to my existing pool. Pool was built in 2015 and I have a manual 3/4” fill line run to one of the skimmers. I’m thinking maybe there is a place to install an electronic water level sensor and add an automatic valve actuator on the fill line.
  24. J

    Taylor Borate Test Strips

    Anyone have any info on the Taylor borate strips being sold on TF Test Kits? Are they better than the Lamatte strips?
  25. J

    Peristaltic pump for swimming pools

    The 2 pumps I listed above will overcome 100 PSI main pump. More than enough.
  26. J

    Pentair 1 hp pump dead.

    He said he put the light switch on temporarily for testing purposes (I wouldn’t have done that as I would have jumped it out to test). Not properly grounded is an assumption.
  27. J

    Pentair 1 hp pump dead.

    I disagree with that statement. As long as the pump is properly repaired and properly wired in (including proper grounding and bounding) there is no reason to replace it.
  28. J

    Peristaltic pump for swimming pools

    2 purposes… to prevent a vacuum from building up as the liquid level goes down, and that’s where the 1/4” tubing going to the pump passes through the tank.