Search results

  1. W

    Another build issue - tabletop height

    Unfortunately I didn't check the column height relative to the waterline tile before the fabricator installed the top. I falsely assumed (and even asked) that the builder had poured the column high enough for a standard thickness granite top to sit out of the water. Turns out - when the water is...
  2. W

    Diamond Brite Plaster - Temperature

    I'm in WV for location context. My pool build started July 3rd and I'm currently sitting with a gunite shell and no plaster. From what I've read about the application: All materials and effected areas should remain above 50°F / 10°C (fifty degrees Fahrenheit / ten degrees Celsius) or below 100°F...
  3. W

    Amount of sand when using Polystyrene Foam Board

    Hi all, I tried searching and reading through prior discussions on the topic but it seemed like most posts were of the either/or variety. I am in the process of installing a new 15x30x54" AGP. I plan to use foam board from Lowes, 3/4" thick and a foam cove. I was wondering how much sand to use...
  4. W

    Top Rail - 15x30 - Beaded Liner - Question

    So this may be a really dumb question but is the top rail necessary for the pool I described/pictured? The reason I ask is this- the deck that was built around it (came with our house) was in need of some repairs so we started cranking away on that. Well, they built the deck over the top rail...
  5. W

    Opening Pool for Summer - Issues testing for CYA, etc

    I cannot, for the life of me, get an accurate test for CYA. 10k gallons, vinyl, above-ground. Last year when I bought my kit, the CYA test did not register after multiple tries. I added CYA (I forget exactly how much, enough to get it to 40, via sock).Tested sometime later, no reading. So I went...
  6. W

    Added CYA But Still Testing 0

    So I added 4lbs of Nava Stabilizer last Friday (I was out of town at the time so I had my mom slowly add it to the skimmer instead of having her attempt to use the sock method). My test kit kept reading 0 but since it hadn't quite been a week, I let it slide. I went ahead and took a sample into...
  7. W

    Question- Preparing to Shock but CYA is ZERO

    First, so happy to have found this site! I've read through pool school and numerous threads and the info has been very helpful. I've spent more money than I want to think about trying to get my pool from cloudy to clear- relying on the pool store to test my water and sell me a solution. I have...