  1. P

    Davey Pump - Australian Wiring Confusion

    It's a special use pump, a good pump, just need to get it wired :)
  2. P

    Davey Pump - Australian Wiring Confusion

    Hello, i am sure there is an electrician that can answer this very easily. I am familiar with the breaker and panel for wiring a standard US 240V 60Hz. I have an australian Davey pump that obviously has the following: brown = hot blue = neutral yellow/green/yellow = ground The pump calls for...
  3. P

    Waterline Tile Installation

    We are using an italian glass tile. It's frost rated, etc. We used soapstone as the coping, which i've included a picture of that as well. The soapstone has been installed since that picture.
  4. pool tile.jpg

    pool tile.jpg

  5. pool tile2.jpg

    pool tile2.jpg

  6. P

    Waterline Tile Installation

    We are going to be installing waterline glass tile here next week on a pool renovation. We are thinking of using a tile contractor who we have used on the interior of our home, and they have done many outdoor water features, but not a waterline pool tile installation. The pool contractors...
  7. P

    Soapstone Coping Installation on standard gunite beam

    What do you recommend as mortar bed thickness? And, do you let it set up a little so it does not all just get pushed out when we set the stone on it? And by rich mix, do you mean add more cement to the mix? I was just going to use sakrete type s mortar mix. Wife wants very narrow...
  8. P

    Soapstone Coping Installation on standard gunite beam

    Plaster will be dark. Yes. Will send you completed pic..
  9. P

    Soapstone Coping Installation on standard gunite beam

    I have experience in setting tile, building block walls and then skimming with stucco. Was just curious if there was anything more specific in the "industry" they are using on coping. Thank you for the suggestion!
  10. P

    Soapstone Coping Installation on standard gunite beam

    Hello, We have an in-ground standard 40X20 pool with an infinity spillway to a lower basin. The upper and lower basin are your standard pool design with Gunite. The soapstone coping are 12" deep X 3 and 4 foot sections long. Heavy! My question is should i use a standard S Type Mortar Mix...
  11. P

    Pentair EasyTouch Screenlogic

    Figured it out. Somehow the easytouch main control panel was put into manual/service mode and that prevents you from controlling the system through screenlogic. Switched it back to auto and voila, works perfectly.
  12. P

    Pentair EasyTouch Screenlogic

    I have a recent problem and I am not sure where it came from. We have an easytouch 8 and installed screenlogic to connect. Initially, everything worked fine from the screenlogic. However, now when i click on the aux1 (which is the pressure pump) it does not come on. On my ipad, it goes to...
  13. P

    Pentair Easy Touch MasterTemp comes on for second and then goes dark

    Ok. I figured it out. I thought that the mastertemp natively had its own thermostat. I guess when you hook it up to the easytouch you have to have the easytouch thermostat installed. I just inserted the easytouch temperature sensor into the pipe and the heater comes on. What a learning...
  14. P

    Pentair Easy Touch MasterTemp comes on for second and then goes dark

    Hello, The saga continues. First time pool owner, but have had pools for many years growing up. Definitely first time for automation. I just installed a pentair easy touch 8, mastertemp 300, intellichlor, etc. I finally found the fireman's switch, installed the 220 line to easy touch...
  15. P

    Pentair MasterTemp Wiring to Easy Touch Where is Jumper?

    Ok, all hooked up, but mastertemp is not turning on. I read other posts by others having the same problem. Thoughts?
  16. P

    Pentair MasterTemp Wiring to Easy Touch Where is Jumper?

    ok, found it. It was hidden behind instructions :)
  17. P

    Pentair MasterTemp Wiring to Easy Touch Where is Jumper?

    Ok. So what is the blue wirecap? Is that the 2 wire going to the easy touch unit? i.e., which two wires go the the EasyTouch? It looks like one of those wires goes to a fuse?
  18. P

    Pentair MasterTemp Wiring to Easy Touch Where is Jumper?

    that is not my heater. I have a pentair mastertemp 300.
  19. P

    Pentair MasterTemp Wiring to Easy Touch Where is Jumper?

    Hello, I recently installed a MasterTemp 300 and about to hook it up to my EasyTouch, however i am confused as to exactly where the "fireman's Switch" is that i need to disconnect. As a note, i will be hooking up a screen logic to the easy touch as well. In another post, i received this...
  20. mastertemp4.jpg

    mastertemp4.jpg

  21. mastertemp3.jpg

    mastertemp3.jpg

  22. mastertemp2.jpg

    mastertemp2.jpg

  23. mastertemp1.jpg

    mastertemp1.jpg

  24. P

    Pentair Easy Touch Wiring Box Not Lighting Up

    Do you have a picture of this? When you say remove the red jumper wire, where do you put it? Also, on the back side of the mastertemp when you remove the panel, there is an on/off switch. What is that for? It is just above where the gas line is wired in.
  25. P

    Pentair Easy Touch Wiring Box Not Lighting Up

    Wow, you should write the instructions for Pentair! You boiled it down very succinctly. Question, referring back to my initial picture on the relays, line and load... i do not hook both the Pump and Heater and Intellichlor to the same relay do I? How would they all fit in under the terminal...
  26. P

    Pentair Easy Touch Wiring Box Not Lighting Up

    Yes, my next hookup is the Heater and IntelliChlor. I feel yet some more questions will need to be answered :) The heater says that it needs to be hooked up to the pump in case the pump breaker, etc. goes off. The IntelliChlor says that it also has to be hooked up to the pump relay. Does...
  27. P

    Pentair Easy Touch Wiring Box Not Lighting Up

    Update: Connected as directed and all is working perfectly.
  28. P

    Pentair Easy Touch Wiring Box Not Lighting Up

    my easy touch does not have a salt water chlorinator in the load center. I have a separate box that mounts external to that. The only transformer in my box is the transformer for the ET control, nothing else. - - - Updated - - - I plan on rerunning thicker gauge for L1 and L2. I recently...
  29. P

    Pentair Easy Touch Wiring Box Not Lighting Up

    in the intellitouch manual page 27 it says rewire for 220 volts, black 120, yellow 120 and blue/violet cap i believe?