  1. C

    Aquarite s3 Omni no water temp sensor.

    I know that. I was saying I have a bunch of sensors left over because most systems only use 2 but they always send 3.
  2. C

    Aquarite s3 Omni no water temp sensor.

    I get that. I probably need to just skip the heater portion because it comes up before all the sensors and then come back and add it.Or pick a different startup option.
  3. C

    Aquarite s3 Omni no water temp sensor.

    The plan is to swap sensors. If that doesn’t work. I’ll put the pump in stand alone get water moving to see if in fact the air temp is affecting the resistance to give an invalid reading and go from there.
  4. C

    Aquarite s3 Omni no water temp sensor.

    That is from a regular Aquarite S3. I have the Omni version which uses the controller instead of the tiny little display. I didn’t get past the heater part of programming because it said there was no water sensor. It’s a little different on the initial setup than an OmniPL or OmniLogic. It has...
  5. C

    Aquarite s3 Omni no water temp sensor.

    I have been to Hayward training a few times. I just wanted to know if the sensor selected for water had to actually be in water… 🤷‍♂️ not much info on that. I have a ton of sensors left from OmniPL installs. They send 3 in case you have a spa but most installs it’s just a pool.
  6. C

    Aquarite s3 Omni no water temp sensor.

    Yeah everything hooked and in the right spot. I haven’t switched out the sensor yet to see if it’s bad.
  7. C

    Aquarite s3 Omni no water temp sensor.

    Good idea. I hope it’s not the board
  8. C

    Aquarite s3 Omni no water temp sensor.

    I have installed the Aquarite S3 Omni at my house finally! Going through programming and I get stopped trying to do the heater. It says I can’t because there’s no water temp sensor. My pool is closed so there’s no water in the pipe but I thought it wouldn’t matter. Searched around no dice . my...
  9. C

    Hayward Aquarite S3 Omni Upgrade kit + Lights

    Yes. I don’t think you can double tap to the same relay and have both transformers running. So it will be a little different setup than your old controller . You will have to activate the light groups separately. Unless anyone else thinks you can double tap or use both sets of contacts on the relay.
  10. C

    Hayward OmniHub Install Not Recognizing Smart Relay

    Sounds like to me you might want to get it escalated higher up. Like the guy who had super old firmware and went to upgrade his MSP and it bricked the controller. They had a Hayward engineer come out and replace it. He then took the old controller with him to figure out why it bricked. It’s...
  11. C

    Hayward Aquarite S3 Omni Upgrade kit + Lights

    Not very familiar with color logic controller. If both of your High Voltage relays are free you can use them for each of the transformers you have. Power from the breaker on line side of the relay in. Load side out to the transformer. Did you have to use 2 transformers because you have more than...
  12. C

    LED too intense

    Most low voltage transformers have 3 taps of different voltage 12 13 and 14. You could try looking at which one you are wired to and go for the lower one.
  13. C

    Trash Pump vs Portable Pool Pump for Initial Cleaning

    I do post construction/concrete clean up for all of our jobs. We had a broken filter that I fixed and an undersized pump we would never use. If the water wasn’t too bad I would use the filter. If it was horrible I would just vac to waste. Hayward c4030 filter and a vsp 500. David and Goliath.
  14. IMG_2344.png

    IMG_2344.png

  15. C

    Anyway to remotely control hayward Tristar VS900?

    Oh you didn’t end up getting the OmniHub? I must have misread your post.
  16. C

    Anyway to remotely control hayward Tristar VS900?

    OmniHub will control the tristar 900 through the rs485 com bus. Control the speeds and set schedule. Way better than using HVR.
  17. C

    Upgrading Omnihub Firmware from 3.0.0 to 5.0.1 via USB - Reboot not completing

    As far as I know the issue should be resolved. Newest firmware is 5.0.4 now as of January 2025
  18. C

    2" pipe connections

    Don’t forget the good ole 22.5 back to back opposite can give you a straight offset of about and inch or so.
  19. C

    Pump not coming online after power loss

    Did you try pressing the offline on/off button on the smart relay ??
  20. C

    Hayward heat pump with Pentair intellicenter

    Hayward is not very good at updating their manuals. That wiring diagram might not be updated. If they have the newer model they can have full functionality of heat and chill through rs485. Although I’m not sure if it could work with pentair because Hayward uses their HUA “Hayward unique address...
  21. C

    Hayward heat pump with Pentair intellicenter

    You have to put the heater into BO mode for it to get a call for heat from the automation. Is it the round heat cool model? If so there might be an RS-485 com connection you can use. Newer models came out with that after people complained about not having full functionality of the heat/cool with...
  22. C

    New pool heatpump

    What model heat pump?
  23. C

    Hayward vs 500 cleaning filter extra part?

    You say a Hayward vs 500? That is a pump model not a filter.
  24. C

    Sense & Dispense + Aquarite with Omnihub

    The S3 series lets you put the unit into slave. I believe you have the older version which is an all metal cabinet with a dial for output instead of a digital display. I haven’t used one of your models in slave mode but I think it’s a jumper that needs moved. I’m not sure I just checked a bunch...
  25. C

    Sense & Dispense + Aquarite with Omnihub

    Anytime and Omni hub,Pl, or Logic has complete control of a device that requires a flow switch it needs to be plugged into the Omni. You could just get another flow switch if you have the room to plumb it up. If you put your Aquarite into slave you should not have to plug flow switch into it.
  26. C

    Three Jets and a Skimmer

    Yeah bad return placement. One in splash pad one opposite of the skimmer and one opposite of the splash pad would be ideal.
  27. C

    Hayward OmniHub and Pentair SuperFLO VST

    Can you show us some pictures of the wiring at the pump and OmniHub? Specifically the com wire.
  28. C

    Hayward OmniHub and Pentair SuperFLO VST

    Yeahp. Firmware update everything. Make sure the dip switches on the pump are set correctly. Make sure the breaker to the pump is off for 10 minutes before changing dip switch settings.
  29. C

    GVA actuator issue

    https://hayward.com/media/akeneo_connector/asset_files/0/9/092051B_RevE_fbb3.pdf
  30. C

    GVA actuator issue

    Start with the bottom cam activating one of the switches and put the top cam at 12 o clock. Use On 2 for the toggle switch and check the action. If it’s going the wrong way use On 1 on the toggle switch. If it’s still not going the right direction turn the bottom cam to activate the opposite...