Aquarite cell not generating

TFP is a registered 501(c)3 non-profit that is maintained by user donations.

The people who answer questions are volunteers.

If you find the site to be a good resource, please consider making a donation to help support the site.

Thanks.

 
off for a minute and back to auto
2000
87
32.4
3.41

72p
-2300
al0
1.55
t9
measured salt 2700
As indicated above in red, you need to wait for at least 10 seconds or wait until you hear the relay click before pushing the diagnostic button to prevent this error.

For the issue with the display board, the use of an electronic contact cleaner as suggested previously in this thread, is ideal.
Fyi, only the top side of the 7-pin header on the mainboard is making contact with the display bd. Make sure the connector on the disp bd is not corroded.
I had a similar issue and a few runs of fine-grit sandpaper on the top side of the header as shown below worked for me.
Aquarite 7-pin ext. header.jpg
 
As indicated above in red, you need to wait for at least 10 seconds or wait until you hear the relay click before pushing the diagnostic button to prevent this error.

For the issue with the display board, the use of an electronic contact cleaner as suggested previously in this thread, is ideal.
Fyi, only the top side of the 7-pin header on the mainboard is making contact with the display bd. Make sure the connector on the disp bd is not corroded.
I had a similar issue and a few runs of fine-grit sandpaper on the top side of the header as shown below worked for me.
View attachment 643973
Thanks so much. I was wondering about waiting for the click. I can do the test again and send results and will also look for corrosion.