- Jul 21, 2013
- 65,181
- Pool Size
- 35000
- Surface
- Plaster
- Chlorine
- Salt Water Generator
- SWG Type
- Pentair Intellichlor IC-60
The chlorine was bottled around March 3, 2025. Fresh stuff.and all had this expiration. 062. Does that mean like March 1 ish…?
The chlorine was bottled around March 3, 2025. Fresh stuff.and all had this expiration. 062. Does that mean like March 1 ish…?
Okay good. I do know how to read them hahaThe chlorine was bottled around March 3, 2025. Fresh stuff.
Length | Width | ||||||||
Feet | Inches | Feet | Inches | Length | Width | Depth | Cubic Inches | Gallons | |
Top Volume | 37 | 0 | 18 | 0 | 444 | 216 | 39 | 3,740,256.00 | 16,191.58 |
4 corners | 48 | 48 | 36 | -165888 | (718.13) | ||||
Slope Sides | 168 | 48 | 56 | 327936 | 1,419.64 | ||||
Ramp | 14 | 0 | 10 | 168 | 120 | 56 | 564480 | 2,443.64 | |
Deep Sides | 4 | 4 | 48 | 48 | 56 | 129024 | 558.55 | ||
Center Mass | 10 | 6 | 120 | 72 | 56 | 483840 | 2,094.55 | ||
End Ramp | 10 | 4 | 120 | 48 | 56 | 239211.5 | 1,035.55 | ||
Corners | -80 | ||||||||
22,945.37 |
Oh okay. So the PB wasn’t too far off. He probably didn’t take into account the shelf when providing me with the gallons for the pool. I thought maybe with the actually diagram we could figure out the exact amount. Thanks againAs I said, use 25K.
I get 23K not including the shelf. Start with the 25K I suggested and use chemicals to adjust volume from there.
Length Width Feet Inches Feet Inches Length Width Depth Cubic Inches Gallons Top Volume 37 0 18 0 444 216 393,740,256.00 16,191.58 4 corners 48 48 36 -165888(718.13) Slope Sides 168 48 56 3279361,419.64 Ramp 14 0 10 168 120 56 5644802,443.64 Deep Sides 4 4 48 48 56 129024558.55 Center Mass 10 6 120 72 56 4838402,094.55 End Ramp 10 4 120 48 56 239211.51,035.55 Corners -8022,945.37
The plans are wall height so the PB is probably right and when we subtract 6 inches for water height (about 2500 gallons) its a hair over 20K.I get 23K not including the shelf
Length | Width | ||||||||
Feet | Inches | Feet | Inches | Length | Width | Depth | Cubic Inches | Gallons | |
Top Volume | 37 | 0 | 18 | 0 | 444 | 216 | 34 | 3,260,736.00 | 14,115.74 |
4 corners | 48 | 48 | 34 | -156672 | (678.23) | ||||
Slope Sides | 168 | 48 | 56 | 327936 | 1,419.64 | ||||
Ramp | 14 | 0 | 10 | 168 | 120 | 56 | 564480 | 2,443.64 | |
Deep Sides | 4 | 4 | 48 | 48 | 56 | 129024 | 558.55 | ||
Center Mass | 10 | 6 | 120 | 72 | 56 | 483840 | 2,094.55 | ||
End Ramp | 10 | 4 | 120 | 48 | 56 | 239211.5 | 1,035.55 | ||
Corners | -80 | ||||||||
20,909.42 |
I’m spot on 3600 on salt. And I was going off the 22800 number.The plans are wall height so the PB is probably right and when we subtract 6 inches for water height (about 2500 gallons) its a hair over 20K.
Pas, how is it behaving when you add stuff ? Have you seen said discrepancy with everything or only bleach ? I trust salt / cya / ch / baking soda (etc) alot more because they don't go in weaker than claimed like bleach might.