- Jul 6, 2015
- 29
- Pool Size
- 1
- Chlorine
- Salt Water Generator
- SWG Type
- Hayward Aqua Rite (T-15)
Hi There, We just opened our pool and our aquarite SWG is not working (no lights/display). We have been trouble shooting using the info provided through this forum (the Hayward Aquarite SWG Further Reading page and related threads). We seem to have the same problem a a thread from Aug 13 2021 posted by GPCMommy. We also had one of the yellow wires that looked burnt at the end. We have cut/crimped the wire, replaced both bridge rectifiers and also replaced the fuse. We have power coming out of one yellow wire (the one that looked burnt) but not the other one. No power in either of the black or red wires connected to the bridge rectifiers. Visually everything looks good. Any ideas what we should try next? It is roughly 10 years old.