Diagnostic Displays Sequential pushes of the small “diagnostic” button next to the LCD display will cause the Aqua Trol to display the following information:
1. Pool temperature (xx degrees Fahrenheit or Celsius)
2. Cell voltage (typically xx.x volts when chlorine is being generated, otherwise 30-35V)
3. Cell current (typically x.xx amps when chlorine is being generated, otherwise 0 amps)
4. Desired Output % (“0P” -- “100P” depending on knob position )
5. Instant salinity ( -xxxx ppm or -x.xx grams/Liter)
6. Product name sent to the display (“AL-6” signifies “Aqua Trol” (STD), (“AL-7” signifies “Aqua Trol Return-Jet”)
7. Software revision level (r1.xx) 8. Salt Mode (nSlt = Normal Salt Mode, lSlt=Low Salt Mode)
On the 9th push of the button the display will revert back to the default salt display.
Also, if the button is not pushed for 30 seconds, the display will revert back to the standard salt display
In this picture, the timer is Off and the system will not work.
The timer needs to be On.