Aqualink PS6 installed instead of P8

May 24, 2010
200
Dallas, TX
Hello! Have a brand new build going; we just filled and PB came out to get pump circulating for startup. Tech realized we had a PS6 installed instead of the P8 we signed for. He went ahead and flashed it to the non-spa version because, well, we don't have a spa :) I'm not super concerned with having 2 less aux circuits- I wanted to max it out for future use, but we've still got 3 free (as opposed to 5). Am I missing anything else at all besides the 2 extra aux circuits?

Thanks!
 
The P8 would have come with enough relays for 8 circuits. If you paid for the 8, they should, at least, provide the extra relays yo paid for as they aren't inexpensive and good to have on hand if and when one goes bad (which could take many, many years).
 
The P8 would have come with enough relays for 8 circuits. If you paid for the 8, they should, at least, provide the extra relays yo paid for as they aren't inexpensive and good to have on hand if and when one goes bad (which could take many, many years).
Gotcha- yup, inside the control panel, looks like there's space for them (2 are for "P6/PS6 only" and the next two are for "P8/PS8 only", or something to that effect). Thanks!
 
That's interesting- so if I did get a P8, it doesn't automatically ship with enough relays to cover all 8 slots (if I'm reading you correctly)?

It depends on the bundle you get. In some cases maybe. Mine did not. The relays are like $25 each.
 
Thread Status
Hello , This thread has been inactive for over 60 days. New postings here are unlikely to be seen or responded to by other members. For better visibility, consider Starting A New Thread.