New Master Temp - IGN ERR

srikantheee84

Well-known member
Sep 15, 2021
117
Austin, TX
Pool Size
29000
Surface
Plaster
Chlorine
Salt Water Generator
SWG Type
Pentair Intellichlor IC-40
I’m trying to start a new master temp connected recently. Once I start I see fan blowing and after sometime I see IGN ERR. Any idea what might be happening here? Thanks!
 
This is not a silly question as I've seen it on too many installs. Are both the gas cock (outside valve) AND the main gas valve (inside the cabinet) in the "On" position? Sometimes a gas cock is installed at the meter as well (a second one). If this is propane (you don't say) is the valve on the tank open?
 
This is not a silly question as I've seen it on too many installs. Are both the gas cock (outside valve) AND the main gas valve (inside the cabinet) in the "On" position? Sometimes a gas cock is installed at the meter as well (a second one). If this is propane (you don't say) is the valve on the tank open?
It’s natural gas. Here is the valve position pics.
 

Attachments

  • 8C2C6C0C-F3EE-44C4-A0CE-987A73D50EA0.jpeg
    8C2C6C0C-F3EE-44C4-A0CE-987A73D50EA0.jpeg
    541.6 KB · Views: 17
  • 0190E658-A4BE-4E88-B8B1-255DECD34A6E.jpeg
    0190E658-A4BE-4E88-B8B1-255DECD34A6E.jpeg
    788.2 KB · Views: 17
Both open. How about inside? Is that heater new or "new to you?" The exhaust side looks like this heater has been in service. If so, you need to do some troubleshooting with multimeter or have an experienced pool tech do it. Do you smell gas when the heater attempts to light? If not you are not getting gas to the combustion chamber. First place to start - gas supply.

On a side note, if you have a 400k btu heater, your main gas meter is too small, likely rated at 275 cfm max. A 400K heater wants 400cfm to function properly.
 
  • Like
Reactions: srikantheee84