The weather forecast for South Texas is an unprecedented, extended freeze. I have a two pump IntelliFlo system. One pump drives the filter, the second a water feature. When it was installed, automatic freeze protection (pump turns itself on at 38 degrees) was engaged on the filter pump but not on the water feature. It's never been cold enough to matter before, but now it does. If you have an IntelliFlo pump and want to engage this feature, I just dug through the manuals: Menu>Settings>Circuit Func.>Name of Circuit You Want to Change>Freeze:Yes.

Lots of additional helpful advice on TFP, thanks for all of it and good luck to everyone. ✌️❄️🤞
 
Like you, I have the same setup. If you have the Screenlogic app, you can also enable freeze protection for the pumps under the Screenlogic setup app, under Setup Circuits- turn on "On with Freeze" by configured circuit. Alternatively, since the weather will be at freezing or lower until mid week, you can just turn these features on permanently until it's over.
 